Thermal Energy Storage (TES) technologies particularly chilled water storage are being applied increasingly by Services Engineers in the Kingdom of Saudi Arabia to reduce electrical demand and lower energy consumption in buildings. This development has received added impetus by the introduction in 1995 of the Load Reduction Programme by the electricity supply authority. The programme aims at managing the shortfall between available electrical supplies and the rapidly increasing demand.
Design for good indoor air quality IAQ) aims to prevent occupant discomfort, irritation, and illness. Sick building syndrome symptoms, discomfort and irritation can easily be the result of other, non-IAQ environmental variables. There is evidence that many such symptoms or complaints result from noise, poor lighting, lack of privacy or control, and other environmental factors that can cause these symptoms and complaints.
Fifty six office buildings in nine European countries were audited during the heating season of 1993-1994 using an agreed upon procedure to investigate the indoor air quality and energy consumption. The results of this IAQ-Audit project show that the largest indoor pollution sources in office buildings are construction materials furnishings and indoor activities, immediately followed by the HV AC systems themselves. Thus, priority must be given to source control.
Mixed mode buildings are attracting a considerable amount of interest due to their apparent potential to deliver comfortable, healthy conditions with significant energy and environmental benefits. BRE and WBA are currently engaged in a three year research programme to generate the guidance necessary to achieve the effective integration of various mixed mode strategies into the most appropriate building forms, considering the occupying organisation's mode of operation. The project will culminate in the production of a CIBSE Applications Manual.
There has been a recent growth of interest in the use of passive cooling in buildings, particularly in the use of chilled ceilings, including both beams and radiant panels. However, there is still concern about the risk of condensation on cold surf aces and water dripping onto occupants or furnishings, especially where there is no control over the level of humidity for instance in naturally ventilated buildings.
This paper reports the findings of a pilot field study carried out to investigate the internal and external pollution levels in two buildings, one naturally-ventilated and the other air-conditioned and to investigate their relative attenuation of external pollution levels. The study is a precursor to more extensive studies aimed at providing guidelines for the design of energy-efficient buildings with a good indoor environment in urban areas.
Computational fluid dynamics (CPD) modelling is increasingly being used as a tool for predicting ventilation rates and air flow patterns as part of the building design process. The potential benefits of this form of modelling are that designs can be optimised to make the most efficient use of ventilation, and so to increase air quality and decrease energy use. Although CFD has shown itself to be a powerful tool in the nuclear, aeronautical and electronics industries for over two decades, its reputation has been built on extensive work specific to those fields.