The use of earth tube system as a means of improving indoor thermal comfort in South China.

This paper reports on an investigation of the use of an innovative earth tube ventilation system designed to improve the internal comfort conditions without the need for mechanical cooling. The numerical model and computer simulation developed for the prediction of air and soil temperatures has been made. The paper demonstrates the accuracy of this model and describes the results of analysis.

Design criteria for warm humid climates: a case study.

Natural cross ventilation to take advantage of air velocity in getting comfort, and solar protection, are the main design criteria traditionally proposed for warm humid climate. Usually, priority is given to natural ventilation related to design decisions such as orientation and windows (size, location and type). However, the wind is the most variable climatic factor, also affected by the urban context, the architectural shape and even, opening and closing windows and doors.

Cost effectiveness of some remedial measures to control summer time temperatures in an office building.

This paper presents a summary of calculations on the total cost effects of the remedial measures to reduce high summer time room temperatures in a hypothetical building. In the base case the room air temperature is too high during the summer, and causes a considerable reduction in the productivity. The following economical items are included in the study: first cost of the remedial measure, the effect of the measure in operating cost, particularly on energy consumption, and the effect on productivity.

Productivity and indoor environment.

Surveys in several office buildings have shown that crowded work places, job dissatisfaction and physical environment are the main factors affecting productivity. the data was produced and analyzed using occupational stress indicator in conjunction with the analytical hierarchical process. thermal problems, stuffiness, sick building syndrome factors and crowded work places were most frequent complaints. the results suggest that the productivity could be improved by 4 to 10% by improving the office environmental conditions.

Air quality measurement in a model kitchen using gas and electric stoves.

Epidemiological studies suggest that cooking with gas leads to an increase of air pollutants and may enhance symptoms of respiratory diseases. However, little experimental data are available concerning the emission of pollutants due to different cooking processes. The goal of this study was to investigate the influence of cooking under standardized conditions on the indoor air quality. A model kitchen was built and three different gas stoves and one electric stove were included in the study. Two different menus were prepared with different settings of the ventilation rate of the exhaust.

Baseline indoor air quality pollutant characterisation in five United States schools.

This paper summarizes baseline results from the U.S. Environmental Protection Agency's (EPA) school demonstration studies. Indoor pollutants of concern were formaldehyde, sum of targeted volatile organic compounds o:VOC), carbon monoxide (CO), particulate matter less than 2.5 microns (PM2.5), particulate matter less than 10 microns (PM10), and bioaerosols (bacteria, fungi, and thermophiles). The five schools presented here had no significant indoor air quality problems. Locations of these schools were distributed throughout various climate zones in the United States.

Connection between ultra-fine aerosols indoors and outdoors in an office environment.

Measurement campaign was conducted in a controlled office environment during January 1999 to get indoor/outdoor ratio for particles less than 0.5 micrometers in diameter. Aerosol concentrations for diameters between 7-500 nanometers were measured simultaneously indoors and outdoors with two DMPS systems. Other continuously measured quantities included temperature, ventilation rate, relative humidity, air pressure and four inorganic gases (S02, NO, NOx and 03). The measured room was practically airtight and had a mechanical ventilation system.

Assessment of the effect of air filtration and ventilation on reduction of exposure to submicrometer particles indoors.

The provision of a healthy and satisfactorily clean indoor environment requires that consideration be given to a range of issues, such as the type of indoor environment, indoor and outdoor sources, indoor activity and others. The selection of relevant measures to achieve the required indoor air quality (IAQ) depends on knowledge and understanding of the mechanisms and parameters affecting the concentration levels indoors.