A simplified indoor air quality (IAQ) model has been applied to predict IAQ in an Australian house, using environmental chamber measurements of source strengths, house ventilation and room size. Total volatile organic compounds (TVOCs) was used as the model pollutant in this study. The validity of the IAQ model was initially assessed by comparing model predictions with measurements in the house over a period of time. The root mean square error between the measured and predicted values was 0.039. This model explains 57% of the potential for error.
A survey of the particle-size distribution of 17 polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air was performed in 20 homes in several Japanese cities. Highest PAH concentrations were found in the fine-particle fraction (smaller than 2.5 μm in diameter). The pro· portion of indoor PAH concentrations in fine particles was found to be higher than that of outdoors.
Mary is a person who suffered terrible health problems, most likely stemming from the design conditions in a lab in which she worked. Designers everywhere can learn from her experience.
A survey of environmental tobacco smoke (ETS) controls in California office buildings was carried out to obtain information on the type and distribution of ETS controls in office buildings and to evaluate the effectiveness of various ETS controls. A total of 118 smoking areas in 111 county and city buildings were inspected to collect information on the type of ETS controls. Only 31 % of the smoking areas inspected were physically separated from nonsmoking areas with full floor-to-true-ceiling walls, 25% exhausted air to the outside, and 38% did not recirculate air to non-smoking areas.
This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mass concentrations were measured gravimetrically and bioaerosol concentrations were determined by impaction methods. Occupant activities and number concentrations were determined with 1-min resolution over a 1-week period.
A study of 132 unoccupied and 60 occupied caravans was conducted to determine levels of formaldehyde and factors which may affect these levels. Repeat monitoring was carried out 6 months later in 50 of the occupied caravans. A questionnaire was also used to assess potential factors associated with the recorded levels. Mean formaldehyde levels of 100 ppb in unoccupied caravans and 29 ppb in occupied caravans were recorded. A negative correlation was found between formaldehyde levels and the age of caravans.
An intervention study was performed in a mechanically ventilated office building in which there were severe indoor climate complaints among the occupants. In one part of the building a new heating and ventilation strategy was implemented by renovating the HVAC system, and a carpet was replaced with a low-emitting vinyl floor material; the other part of the building was kept unchanged, serving as a control. A comprehensive indoor climate investigation was performed before and after the intervention.