A Norwegian research project in under progress to develop a new concept for control of air movements in protection isolates, operating theatres and other risk areas in hospitals. The aim is to reduce airborne hospital infections through appropriate design of building, HVAC installation and control of air movements. A container solution was developped for isolates. Its HVAC system, and especially the ventilation system are described in details. The first container has been finished in June 2002 to be tested.
Practical application on two buildings (a movie theater and an office building) of the Indoor Air Quality Procedure described in ASHRAE Standard 62 is demonstrated. It shows in particular how air filtration can achieve acceptable indoor air quality and energy savings (by reducing outdoor air flowrate requirements).
Photovoltaic/thermal hybrid solar collectors (producing electricity and warm air) were simulated with TRNSYS software when used together with a heat pump and an auxiliary gas boiler in a complete system to produce space heating and domestic hot water.
Performance of solar systems used to preheat ventilation air was investigated through long-term (several years) measurements on three buildings in Czech Republic. Buildings and results are described.
An energy audit calculation procedure has been developed for existing buildings. It allows to estimate which measures have to be taken to improve the thermal performance of building envelope. An example of the application of this calculation procedure is presented.
Numerical modeling and on site measurements were applied to the ventilated double-skin glazed façade of the Moravian Library building in Brno (Czech Republic) to determine the air temperatures and velocities into the façade. Calculations show that supply
This paper presents 3 full-scale test rooms in a series of 14 built in Italy, with different types of façades. The measurements of energy consumption and indoor environment allow a direct comparison between different solutions exposed to identiacal climat
CFD calculations and laboratory measurements in a full-scale model were carried out to assess the performance of a full transparent second skin façade intended to equip an office building, composed of very low solar energy transmittance glass, and being v
Indoor aerosol particulate matter (PM) concentrations were measured gravimetrically in 36 carpeted bedrooms of asthmatic children. Particulate concentration was higher indoors than outdoors. High efficiency particule arresting (HEPA) filtration was shown dividing concentrations by about 2.