Modeling an under floor air distribution system

A model of an UFAD system in a ventilated room is proposed , the room is ventilated with one heat source and one cooling vent as a two-layer stratification.

Analysis of the underfloor air distribution system : thermal comfort and energy consumption

That paper presents the results of a thermal comfort evaluation research in a brazilian office building : the measurements show that an underfloor air distribution system can provide comfortable conditions for both sitting and standing occupants along with a reduction of the energy consumption .

Displacement ventilation for room air moisture control in hot and humid climate

Few studies dealing with the effect of displacement ventilation on humidity gradient in a hot and humid region have been made . In this paper it is done with a case-study approach (measurements were made in a factory located in the Tropics). The results indicate that the humidity gradient is as significant as the temperature gradient..

Obstacle effects on airflow and contamination around an open type livestock building

That study aimed at investigating the contaminate distribution in and around a naturally ventilated livestockbuilding with and without an upstream obstacle.

Flow fields and particle trajectories in turbulent type clean rooms with different supply/exhaust air arrangements

A wall return and a ceiling return air arrangements of turbulent type clean rooms are presented in this paper. The influences of obstacles on the flow fields are compared by a numerical simulation.

Airborne particle concentration control for an operating room

Critical parameters such as the particle source location, air supply inlet design, operating table location, and lamp design are responsible for the particle distribution within the operating room, they have been investigated by means of CFD.

Improving CFD Simulation of chilled ceilings

This paper deals with a CFD simulation of a chilled ceiling in a test chamber. The results demonstrate that a slight non-uniformity in cooling power of the ceiling panels produces a great asymmetry in predicted room airflows.

Numerical study of partition-type FCU personal air-conditioning system

The intention of the authors is to find a proper air conditionning system to achieve higher IAQ environment.They consider a new air-conditioning system that uses both a Partition-type Fan-Coil Units system (PFCUs) with a Dedicated Outdoor Air System (DOAS).

Jet drop and draft risk in a mixing ventilation office : experimental and numerical investigations

This paper is a presentation of a theoretical and experimental analysis of supply air jet flow patterns in a mixing ventilation system. Investigation procedure aims at reducing draft risks.

Vertical distribution of contaminant concentration in rooms with floor-supply displacement ventilation

The experiment was conducted by means of a scaled-room wtih floor supply ventilation system, it intended to know the vertical distribution of contaminant concentration emitted from a human body. The validity of the models has been proved in so far as the calculated concentrations were almost equal to the measured values.