Using forced ventilation to mitigate mold growth in existing multi-family housing

Increasing emphasis on energy-efficiency has many jurisdictions enacting stricter energy codes. Yet, these same green building codes typically do not adequately address ventilation when a building envelope is designed to both minimize infiltration/exfiltration and maximize thermal efficiency. Our company investigated an apartment complex in Southern California, U.S.A. that was designed 25% more thermally efficient than required by State Code. Within months of occupancy, the first complaints of biological growth at windows and closets occurred.

Mold in dwellings : field studies in a moderate climate

Mold in dwellings is a persisting complaint in moderate climates. Nine parameters intervene in it: (1) climate, (2) inside temperature, (3) vapor release, (4) ventilation, (5) lay out, (6) envelope thermal performance, (7) sorption inside, (8) presence of preferential condensation surfaces and (9) type of finish. Exterior climate acts as boundary condition while inside temperature, vapor release and ventilation belong to the living habits. The five others are design and construction related.

Development of indoor climate classes to assess humidity in dwellings

The knowledge of indoor air humidity in the design phase is important to decide on the appropriate moisture control measures to prevent moisture problems in building components. Because of the uncertain nature of most of the factors affecting the indoor humidity, its accurate prediction in the design phase is not possible. To overcome this problem, the concept of Indoor Climate Classes has been introduced and used in Europe since its early development in the Netherlands in the 1970s up to its recent introduction in a European Standard on the hygrothermal performance of building components.

A first study of natural and hybrid ventilation systems in the urban environment

An experimental campaign was organized during the summer period 2002 in Athens, in the framework of the European RESHYVENT Project. The main purpose was to indicate the impact of the urban environment on the natural and hybrid ventilation air flow process in urban canyons. Field and indoor experimental procedures were carried out in two urban canyons, presenting different geometric and urban features. The experiments were organized for more than three consecutive days within three different periods in summer and on a 24-hour basis.

IEA ECBCS Annex 36 : retrofitting in educational buildings - REDUCE 25 case study reports from 10 different countries

The IEA ECBCS Annex 36 deals with the energy retrofit of educational buildings. Researchers from 10 participating countries from Europe and the US are collecting information on retrofit measures and case studies and are developing an energy concept adviser for technical retrofit measures. This internet-based computer tool for decision-makers is the main outcome of the annex. One of the most important inputs to the tool is the collection and assessment of case studies, which is also presented in a specific report.

Energy saving through the use of a supply air window

In Arctic and sub-Arctic climates, such as those in Scandinavia, multiple-glazing windows that consist of at least three panes are widely used. Typically, the replacement air for the extracted air, especially in low-cost accommodation with forced extraction, enters the interior space in the form of leakage flow through the window jambs and the walls or through the supply air vents. The temperature for the air entering the room is close to that of the outdoor air, which may cause a sensation of draft.

Total energy performance of the air conditioning system using outdoor air cooling potential

From the view point of designing the energy efficient air conditioning system with maximized ventilation, the possibility of an all fresh air system was discussed using the simulation results of a model building in Tokyo. The algorithm of single duct cooling system for simulating the cooling coil of air handling unit based on the heat balance model of whole system components is also described as a base for the simulation of cooling effect of ventilation fresh air.

Ventilation calculation by network model inducing bi-directional flows in openings

For the multi-room ventilation calculations, bi-directional flows or counter flows in openings have been rarely taken into consideration and only uni-directional flows have been allowed for the calculation. It stands to reason that the calculation requires quite sophisticated scheme and the appearance of the bi-directional flows are restricted only to a limited number of openings neighboring the neutral plane of the building and also the flow rates may be too little to affect the total building

Design and testing of a control strategy for a large naturally ventilated office building

The design for the new Federal Building for San Francisco includes an office tower that is to be naturally ventilated. Each floor is designed to be cross-ventilated, through upper windows that are controlled by the building management system (BMS). Users have control over lower windows, which can be as much as 50% of the total operable area. There are significant differences in the performance and the control of the windward and leeward sides of the building, and separate monitoring and control strategies are determined for each side.

Use of simulation in the design of a large naturally ventilated commercial office building

The design for the new Federal Building for San Francisco includes an office tower that is to be naturally ventilated. The EnergyPlus thermal simulation program was used to evaluate different ventilation strategies for space cooling and rationalize the design of the faade. The strategies include ventilation driven by different combinations of wind, internal stack and external stack. The simulation results indicate that wind-drive ventilation can maintain adequate comfort even during hot periods.