Effects of indoor air quality on office workers’ work performance - a preliminary analysis

We conducted an epidemiological study to examine the associations between indoor climate and office workers’ health and working efficiency. We investigated four office buildings in Massachusetts, USA, beginning May 1997 over 1 year. Ninety-eight participa

Effects of building characteristics on self-reported productivity of office workers: the base study

The objective of this study was to evaluate the effects of building characteristics on selfreportedproductivity using the Building Assessment Survey Evaluation (BASE) dataset. Ofthe respondents surveyed, 28% reported one or more lost workdays over the last month due tobuilding-related symptoms, and 40% reported reduced ability to work.

Individual control of air velocity for increasing productivity

Subjective experiments were conducted in a climatic chamber to evaluate the effect ofindividual control of air velocity on productivity. For the condition of constant air velocity(CAV) subjects were not allowed to control air velocity and for the condition of preferred airvelocity (PAV) they were allowed to control it. The chamber was conditioned at airtemperatures of 31C, mean radiant temperature of 31C, and relative humidity of 50%. Severalcomputer tasks were given to the subjects to evaluate task performance.

Call-centre operator performance with new and used filters at two outdoor air supply rates

A 2 × 2 replicated field intervention experiment was conducted in a call-centre providing a national public telephone directory service: outdoor air supply rate was adjusted to be 8 or 80% of the total airflow of 430 l/s (3.5 h-1); and the supply air filt

The effect of perceived indoor air quality on productivity

A new derivation of productivity calculation model based on pollution loads and contaminantremoval effectiveness is applied and the effect of the improved ventilation efficiency onproductivity is estimated. The findings show that the proportion dissatisfied could be asuitable predictor of productivity loss due to indoor air quality in different kinds of officework. The proportion dissatisfied is possible to calculate from olf and decipol units. In a caseof one person per 10 m2 (0.1 olf/m2) and low-emitted material (0.1 olf/m2), the total sensorypollution load is 0.2 olf/m2.

Indoor climate and perceived comfort in offices

A method has been developed to investigate the comfort in office buildings. It is based onboth measurements and a questionnaire. The measurement apparatus, the so-calledAmbiometer, can record both the main comfort parameters, such as temperature, humidity,noise, light and odours, and the occupant's perceived comfort. Information regarding theindoor climate and the working environment is noted on the questionnaire.Experiments were conducted on about 50 offices in France.

The SBS symptoms and environmental perceptions of office workers in the Tropics at two air temperatures and two ventilation rates

A blind intervention study in which air temperature and the outside air supply rate were changed in a 2 × 2 design was carried out in a call centre in Singapore. The reported intensity of headache and difficulty in concentrating were reduced by 19.5% (P

Examination of influence of CO2 concentration by scientific methods in the laboratory

The goal of the present study was to examine the influence of CO2 concentration in the air ofindoor spaces on human well-being and intensity of mental work. Ten experimental subjectswere used in four experimental conditions with different CO2 concentrations (600, 1500,3000, 4000 ppm). Microclimatic parameters (CO2 concentration, temperature and relativehumidity of the air, surface temperature of walls) were measured.

Objective and subjective responses to low relative humidity in an office intervention study

The impact of dry indoor air on comfort and health in winter was investigated in a crossoverintervention study in two floors of an office building in northern Sweden. The indoor airhumidity (normally 10-20% RH) was raised to 23-24% RH, one floor at a time, using steamhumidifiers. Questionnaires and objective (clinical) measurements were applied.

Initial studies of oxidation processes on filter surfaces and their impact on perceived air quality

Ozone concentrations were monitored up- and downstream of used filter samples at airflowsof 1.0 and 0.2 l s-1. The ozone concentration in the air upstream of the filters was ~75 ppb,while the concentration downstream of the filter was initially ~35% lower at 1 l s-1 and ~55%lower at 0.2 l s- 1. Within an hour the removal efficiency had decreased to roughly 5% at1 l s- 1 and 10% at 0.2 l s- 1. These filter samples were then placed in either nitrogen or ambientair for 48 h. Afterwards it was found that there was partial regeneration of the filters ozoneremoval capabilities.

Pages