Inflow Direction at Large Opening of Cross Ventilated Apartment Building

In case of cross ventilation through the large opening, it is well known that the inflow directionat the opening is not normal to the opening. Authors proposed the simplified prediction method of theinflow direction at the inlet opening and the airflow rate simultaneously. It is also well known that the use of general discharged coefficient (CD) values is not suitable for the calculation of cross ventilation rate. First reason is that the simple connection of the pressure loss coefficient of an opening ( ?? as the reciprocal of square CD) in series under-estimates the airflow rate.

CFD Modelling of Atrium-assisted Natural Ventilation

Using computational fluid dynamics (CFD) techniques to model buoyancy-driven airflows hasalways proved challenging. This work investigates CFD modelling of buoyancy-driven natural ventilation flows in a single-storey space connected to an atrium. The atrium is taller than the ventilated space and when warmed by internal heat gains producing a column of warm air in the atrium and connect space drives a ventilation flow. Results of CFD simulations are compared with predictions of an analytical model and small-scale experiments [1].

Experimental and Numerical Analysis of Wind Driven Natural Ventilation in a Building Scale Model

Airflow through openings in a cross ventilated building scale model was investigated in a windtunnel and by numerical predictions. Predictions for a wind direction perpendicular to the building showed an airflow pattern consisting of streamlines entering the room, that originated from approximately the same upstream area in the undisturbed boundary layer and a direction of the flow into the room dependent on opening location with velocity vectors pointing away from the stagnation point.

Experimental study of transition phenomena in buoyancy-induced natural ventilation

Experiments were carried out to study transition phenomena in buoyancy-induced natural ventilation in a relatively large-scale enclosure equipped with a localized heat source and two openings (upper and lower) on one of the sidewalls. The process studied is transition from the mixing to the displacement ventilation mode realized by opening the lower vent to different heights while keeping the upper vent fully open. Measurements included inside vertical temperature profiles and air velocity through the upper vent.

Determination of the Air Change Rate for Natural Ventilation with Regard to Energy Efficiency and Building Physics

The air exchange in a room with different windows and window geometries is investigated. The aim is to get reliable data for the air change rate and the air exchange efficiency for natural ventilation. Before using a CFD program for the calculations experimental studies have been carried out. In order to meet different demands we distinguish between short time and continuous ventilation. The results are availabe as figures, graphs or approximate equations.

Thermal effects on the dispersion of a gaseous contaminant in a naturally-ventilated room

The influence of thermal effects on the dispersion of a gas in a naturally-ventilated room is investigated using CFD in conjunction with measurements. The gas dispersion inside the room, with and without thermal effects, is characterised by a statistical analysis of the CFD-predicted gas concentrations at a large number of points across the room with a view to quantifying the thermal effects. It is concluded that even small temperature differences can lead to significantly different cross flow behaviour and rates of gas concentration decay at the relatively low air change rate considered.

Numerical simulation of the flow field in the kitchen of a residential building with natural ventilation

The main goal of this work is the modeling of the flow field and temperature distribution in thekitchen of a house where natural ventilation techniques were implemented. The Fluent 6.1 commercial CFD software was used. The k- e turbulence model and the Boussinesq approximation for buoyancy were employed. The heat released from a water heater in continuous operation dictates the temperature distribution in the kitchen. Several simulations were performed by varying the boundary conditions and seeking agreement with the available experimental data.

Numerical Evaluation of Wind Pressure Distributions of Buildings by Means of a Modified k-e Model

A modified k-e model that restricts turbulent time scale using Durbin’s limiter was applied for numerical prediction of wind pressure distributions of building models. It is known that the standard k-e model tends to overestimate wind pressure of windward

On the night purging of naturally ventilated enclosures - the effect of the relative area of openings

We consider the overnight evolution of an initial two-layer thermal stratification (a warmupper layer and a cooler lower layer) in an enclosure ventilated via openings at high and low levels.Results of our laboratory experiments show that an efficient displacement flow is not always established and four distinct ventilation flow regimes are observed depending on the ratio R (= at /ab ) of the upper opening area, at , and lower opening area, ab ( > 0). For a given initial stratification, displacement flow is established only if R is sufficiently small (i.e. at

Natural Ventilation with Pre-cooling

We investigate two different natural ventilation regimes of an auditorium or other occupied open-plan space which is equipped with pre-cooling. The room has a low-level vent and a high level vent. The occupants act as a source of heat, which if without pre-cooling, can lead to the room becoming too warm for comfort. In the first ventilation regime, a chiller is fitted to the low-level vent, and the occupants provide positive buoyancy which drives the ventilation upwards and draws fresh air through the pre-cooling system.

Pages