Contaminant control in the built environment: state of the art summary.

The reduction of ventilation in buildings as an energy saving measure may result in a deterioration in indoor air quality. Suggests use of contaminant control devices and summarises devices available. These are filters, electrostatic precipitators, mechanical dust collectors, scrubbers, and contaminant combustors Suggests five areas where further research is necessary.

The effect of reduced ventilation on indoor air quality and energy use in schools.

Indoor air quality in an air conditioned California high school has been measured over a variety of ventilation rates ranging from 13.3 cubic feet of outside air per minute for each classroom occupant to approximately 1.5 cfm per occupant.< Parameters measured include outside air supply rate, the occupants' subjective perception of indoor air quality, airborne microbes, carbon dioxide, carbon monoxide, nitrogen oxide, sulphur dioxide and ozone in two classrooms, a halland outdoors.

The radiological implications of using by-product Gypsum as a building material.

By-product gypsum, produced as a waste in the phosphate industry, could be used in bulk as a building material but it has a higher radium content than other building material. Reports an analysis of the dose rate that would result if gypsum were used for a two-storey, three-bedroom, centre terrace house. Discusses the dose from beta radiation, gamma radiation and radon gas,assuming one air change per hour.

Automated air infiltration measurements in large buildings.

An automated air infiltration measurement system for large buildings isdescribed. The system consists of a micro-computer, electron capture gaschromatograph, a ten port sampling manifold, and five tracer gas injectionunits. The system controls the injection and sampling of tracer gas in amulti-zone building, calculates the air infiltration rates of each zone, andmeasures the on-time of events such as HVAC fan operation, exhaust fan operation,and door/window openings.

An advanced dehumidifer for Britain.

States condensation caused by high humidity is a major problem in British homes. Describes a conventional heat pump dehumidifier for removing moisture from the air. Describes the advanced dehumidifier developed by the Electricity Council Research Centre which is designed to work in cold damp conditions typical of British winters. Gives details of the design and reports that tests of a prototype show that the design is more than twice as effective in terms of litres of water extracted per unit energy than conventional designs.

Ventilation and permeability of dwellings. Ventilation et transparence a l'air des habitations.

Describes method for calculating the adventitious ventilation of a building using information from a pressurization test. The method requires a knowledge of the surface pressures on a building, calculated from wind speed and direction, the inside-outside temperature difference, and the distribution and characteristics of openings in the building shell. Applies formulae to threebuildings and finds a great dependence of infiltration on wind direction. Discusses the effect of wind and stack effect, separately and combined.

Air flows in building components.

This work deals with different aspects of air movements in building components. The investigation shows to what degree the concept of fluid mechanics can be applied to problems concerning air flows in building componenets. The applicable parts of fluid mechanics are presented as thoroughly as possible. Based on this concept, routines are outlined to make it possible to handle complex flow and pressure distribution problems. Both manual and computer calculation routines are described and the way they can be used is demonstrated in a number of examples.

Air infiltration research in Finland.

Describes the current research programme of the Laboratory concerning air infiltration and ventilation. Gives some technical details. The programme consists of three main projects: 1) The development of mathematical calculation models to predict the interconnections between air tightness, ventilation, air change rates, pressure conditions and energy consumption. This model will be tested in practice. 2) The development of airtight structures and structural joints and sealing methods. Evaluation of theeconomical effects of airtightness is also included in this project.

Ventilation is often inferior in new, single family houses. Ventilationen ofta dalig i nybygga enbostadshus.

Ventilation measurements in new Swedish houses show that they seldom fulfill minimum requirements of 0.5 air changes per. hour applicable to specific housing classifications. Basic natural ventilation is often used. Discusses consequent problems including condensation and humidity, excess radon daughters and formaldehyde content in the room air. Notes future demands for systems to include heat exchangers.

Carbon dioxide measurement in open-classroom school with outside air-supply damper closed to conserve energy.

In some buildings in Canada ventilation systems are being operated with the outside air supply dampers completely closed during winter to reduce ventilation and hence conserve energy. Reports measurements of the carbon dioxide concentrations in the classrooms of a small elementary school, when the outside air-supply damper was closed, to assess whether ventilation was adequate. Concentrations were found to be well below the maximum accepted occupational standard of 0.5% and air infiltration gave an adequate fresh air supply.

Pages