Energy saving effects in dwellings where measures have been implemented by governmental energy saving grants.

Presents the results from a comprehensive empirical investigation of 1144 swedish buildings in which energy conservation measures eligible for Government funding assistance have been undertaken.

Natural ventilation and energy consumption of dwellings.

Reports on an investigation concerning ventilation and energy conservation in dwellings, which was financed by the EEC and the Dutch Ministry for Housing and Public Works. Concludes that:< 1. In single family houses air flow through cracks and joints causes more ventilation then is required.< 2. Flats with more airtight construction provide better control of ventilation.< 3. The amount of wind protection plays a part as important as airtightness.< 4.

Natural ventilation of rooms:a simplified analytical study. La ventilazione naturale degli ambienti studio analitico semplificato.

Presents an analytical procedure for evaluating the air change rate in a room due to the temperature difference between the interior and exterior, which occurs when a door or window is opened.

Applicability of a measuring method for determining the airtightness of houses. Toepassing en consequenties van een meetmethode voor de luchtdoorlatendheid van woningen.

As part of a study by the Building Research Foundation on control methods for the thermal quality of homes, research has been carried out into the usefulness and consequences of a measuring method for the determination of the the airtightness of houses. Airtightness measurements were carried out in sixhouses. Data on occurring ventilation was already available from other research. It appears that the pressurization test for the airtightness of houses can be used to determine the thermal quality of the home.

An investigation of technical and hygienic aspects of energy saving by reducing mechanical ventilation in a block of flats. Onderzoek naar de mogelijke energiebesparing en technische en hyienische aspekten van het verminderen van de mechanische ventilatie

Measurements were made of the apparent volume flows in the mechanical ventilation system of a block of flats, along with the expected energy arising from domestic ventilation. The aim was to see what energy saving could be obtained by reducing the mechanical ventilation in the block of flats. It was found that this depended on the reaction of the occupants. If they opened an extra vent light for a few hours per day, then the energy losses due toventilation were higher then before the reduction of the mechanical ventilation.

The tightness of buildings studied by international cooperative group. Byggnaders tathet studeras i internationell samarbetsgrupp.

Notes emerging importance of airtightness and preparation of `Air Infiltration Handbook' by Sweden. Discusses the work of the Air Infiltration Centre under the auspices of the International Energy Agency. Reports on second AIC conference hosted by Sweden in September 1981. Discusses main topics presented at the conference dominated by the need for `controlled ventilation' and the problem of measurement.

Energy savings in buildings-a headache which goes beyond the ability of tradesmen. Energibesparing i byggnaden-huvudvark over skraganserna

In terms of energy usage and indoor climate a building works as a total system where the shell, the installations and services interact organically. However, technical knowledge of this total system is still undeveloped and the limitations of different trade categories hinders such development. Examples show how the efficiency of building methods such as tightening external walls depend on the ventilation system used in the building.

Ventilation and infiltration.

Briefly reviews ventilation requirements, types of ventilation , driving mechanisms for natural ventilation and infiltration, natural ventilation, infiltration and air leakage, air leakage sources, empirical models and infiltration measurement.

Air flow around buildings.

Reviews nature of air flow conditions, meteorology affecting building air flow, wind effects on systems operation, and physical modelling and full- scale measurements.

Subjective effects of low speed air movement Subjectieve effecten van luchtbeweging met lage snelheid.

Reports experiments on whether there is an optimum air speed for comfort carried out at the Electricity Council Research Centre at Capenhurst. 9 seated subjects were separately exposed to a steady horizontal air movement over the whole body. At air velocities of 0.1, 0.15, 0.25 and 0.35 m/s the subjects were asked to adjust room air temperature personally to a preferred level. An enquiry list was laid before them. Preference was given to the 10-point Bedford list over the 7-point ASHRAE one. Compares test result figures with Bedford and Fanger theories. Uses the Newman Keuls procedure.

Pages