This work presents a field measurement study, investigating the airtightness of 64 French dwellings less than ten year old. Buildings have been classified according to the type of construction (masonry or timber frame) and of occupancy mode (multi- or single- family). Using a fan-depressurization technique, we assessed the air leakage rate of each dwelling, based on a theoretical flow model that relates the infiltration airflow rate to the differential pressure .
A currently unresolved problem in building design is the paradox between increasing demand for good thermal insulation, and the requirement for ample levels of ventilation, to maintain a healthy indoor environment. A possible solution to this problem is a supply air 'ventilated' window. This utilises an airflow between panes to pre-heat ventilation air to the building, and to reduce thermal convection losses, thus reducing the window Ue-Value.
Painting large objects like cars or trucks usually generates high levels of pollution that can be eliminated by operating in a closed painting booth equipped with a blowing ceiling which produces a vertical ventilation flow. When the process does not allow the work to be carried out in a completely confined space (in the presence of a travelling crane for example) one of the only ways to remove pollution is the ventilated area. A basic ventilated area is merely a floor area of an industrial premises located above a pit equipped with an air exhaust system.
The objective of this project was to provide cool working conditions for a small number of Customs Department staff in a turn-of-the-century heritage building in Town ville at 19° S latitude. A ducted air conditioning system was initially proposed but rejected as it would have been incongruent with the Victorian elegance of the space, as well as its high cost. As the working area in the three storey high space was surrounded by ornate timber counter and partitions, a scheme was developed using fan coil direct expansion units. These were located behind the counter to the public space.
This study involves comprehensive experimental measurements and CFD simulations in a mockup of a full-size classroom with realistic loads. Four different air distribution systems have been tested:
This paper describes an investigation into the ventilation performance and the indoor air quality of a portable classroom. Both field measurements and numerical simulations based on CFD (Computational Fluid Dynamics) technology were used. Field measurements in an unoccupied classroom used smoke to visualize the flow pattern, and hot-film probes to quantitatively measure air velocity. These field measurements provided the boundary conditions for CFD simulations and the experimental data to examine the accuracy of the CFD simulations.
One of the significant factors affecting the quality of air in the built environment, particularly in the context of hot humid climates, is the design and implementation of the air-conditioning and mechanical ventilation system. While most building regulations would incorporate minimum ventilation requirements al design, it is often difficult to quantitatively measure the adequacy of such ventilation provision in insitu buildings.