Thermal comfort requirements from hot-humid to hot-dry regions

This paper shall investigate thermal comfort requirements for university students in the hot-humid region of Bahrain and the hot-dry region of Saudi Arabia. An extensive field survey shall be conducted among university students in an attempt to define optimum comfort requirements. The field surveys shall deal with the following aspects:
Recording climatic variables, which influence thermal sensation, these are; ambient temperature, radiant temperature, relative humidity and air velocity.

The impact of the warmth thermal sensation into non-air-conditioned and naturally ventilated office environments of tertiary refurbished buildings in tropical climate

This paper provides a research about rapid methods and simplified tools to assist the projectactors, such as architects, designers and engineers, involved in the building design, in theearliest conception during the preliminary design. We examine the quality criteria of indoorthermal environment in non-residential existing buildings, with failure in the pre-energyconservation. The main objective is how well to predict a mean thermal comfort sensation forworkers under warm conditions over the tropical climate. The occupants could change theiractivity (metabolic rate) and their clothing.

Thermal comfort in office buildings with underfloor air supply quantitative and qualitative analysis

Thermal comfort in office buildings is usually unsatisfactory when ceiling air distribution isemployed, because it is hard to make adjustments to reach specific occupancy needs. On theother hand, underfloor air distribution allows some flexibility for adjustments. In order toevaluate thermal comfort conditions in office environments with underfloor air supply system,a laboratory facility was built at the Universidade de Sao Paulo, Brazil. In this work,quantitative and qualitative results obtained in such facility are discussed.

Ultra-fine and fine particle formation in a naturally ventilated office as a result of reactions between ozone and scented products

Ultra-fine and fine particle formation as a result of chemical reactions between ozone and fourdifferent air fresheners and a typical lemon-scented domestic cleaner was studied in a fullyfurnished, naturally ventilated office. The study showed that under conditions representativeof those occurring in such offices, air fresheners or scented cleaners may react with ozone toform secondary organic aerosols (SOA). The tested air fresheners were relatively smallsources of SOA with detectable increases occurring only in the ultra-fine particle numberconcentration.

A pilot study on the effect of indoor particle sources on indoor particle concentration in residential houses

Characterization of indoor particle sources from 14 residential houses in Brisbane, Australia,was performed. The approximation of PM2.5 and the submicrometre particle numberconcentrations were measured simultaneously for more than 48 h in the kitchen of all thehouses by using a photometer (DustTrak) and a condensation particle counter (CPC),respectively. From the real time indoor particle concentration data and a diary of indooractivities, the indoor particle sources were identified.

IAQ assessment in a large school of arts worker exposure to fine particulate matter and VOCs

The aim of this work was to assess the influence of the ambient air quality and some indoorsources on the concentration levels of airborne fine particles and volatile organic compoundsin a large school of arts. Measurements were conducted, for both indoor and supply air, ineight office rooms in four floors controlled by four separate air handling units (AHU). Fineparticle measurements by SMPS in the size range 15-700 nm indicate that the placement ofthe HVAC air feed points and different AHUs affect the total particle concentration and sizedistribution in the supply air.

Indoor air quality in two different office buildings - Part 2: Indoor and outdoor airborne particulate levels and air filtration

The study has been carried out in two different French buildings. The main objective of the study was to know more about office buildings’ indoor air quality as well as HVAC installation working over a long period (1 year). A lot of data are available but

Ultrafine and fine particles, VOC and odour emissions from dusty air filters

Fine particles (4 -700 nm), odour and VOC emissions before and after the used supply airfilters were studied in a ventilation unit. The pre-filter (G3) did not collect fine particles at thetest conditions, but acted as a source of particles 50-300 nm in size. The F7 fine filter, locatedafter the pre-filter, collected quite effectively even the finest particles. Sensory evaluationshowed that intensity of odour was highest after the F7 fine filter.

Fungal spore transport through a building structure

That study carried out particle transport measurements for full-scale timber frame structure similar to a wooden floor. The penetration is highly dependent on pressure difference and not on holes in the surface boards of the structure. The results showed that surface contacts of mineral wool with other building elements may have an important role in penetration.

Microbial contamination of indoor air due to leakages from crawl space - a field study

The aim of that study was to find out if a potential air flow from crawl space has an influence on the indoor air quality : is there a potential risk for the first floor apartments ? A balanced ventilation system is recommended.