The 19th AIVC Conference, Ventilation Technologies in Urban Areas, was held in Oslo, Norway, 28-30 September 1998.

Contains 55 papers

Volume content

Enter a comma separated list of user names.
The book of proceedings from the 19th AIVC Conference "Ventilation Technologies in Urban Areas", Oslo, Norway, 28-30 September 1998.
AIVC
Concentration of pollutants produced by car traffic in a street below the roof level has large spatial variations.
Flori J-P, Sacre C
Pre-assessing the reliability of ventilation systems is a dificult task and no simple methodshave existed. This paper presents a tool for estimating the reliability of domestic ventilationsystems.
Ruud S, Kronvall J
Natural ventilation in office buildings can sometimes offer other advantages than traditionalmechanical ventilation systems. Often natural ventilation systems are promoted at an earlystage by an architect, but perceived dificulties, e.g.
Kronvall J, Svensson C, Adalberth K
The principles of a new tracer gas technique is described in the paper. The new technique involves pulse injection of tracer gas and has the same advantages as the previously known homogeneous emission technique.
Stymne H, Boman C A
Filters for gaseous contaminants which are used inside HVAC systems are characterised by means of rated air flow rate, air motion resistance, trend of the mass efficiency versus time and holding capacity of the considered gas.
Anglesio P, Perino M, Tronville P
A dynamic simulation of the ventilation processes and the thermal behaviour of an office building is developed.
van Paassen A H C, Liem S H, Groninger B P
We examine natural ventilation in buildings with multiple storeys, each storey linked to acommon chimney or atrium, and ventilated using 'top-down chimneys' to draw in relativelyunpolluted air from openings located high above street level.
Hunt G R, Holford J M
To conduct a controlled trial to test the ability of a newly developed electrostatic air cleaningtechnology (EAC) to improve Indoor Air Quality (IAQ) as defined by levels of air borne particlesand to investigate the potential to reduce non-attenda
Rosen K G, Richardson G
Good airtightness of a building can be achieved by the incorporation of an inner sealing layerfor the exterior walls and roofs in the form of a plastic film, which also serves as a vapourbarrier.
Sikander E, Olsson-Jonsson A
This paper identifies successful ways of applying natural ventilation to non domestic buildings locatedin urban areas. Whilst noise and contaminant pollution sources are a problem methods of avoiding theseemissions are discussed.
Ajiboye P
Ventilation systems using variable airflow are useful in urban areas. Due to outdoor pollutionand the indoor load from pollution or thermal sources, it is important to vary the airflow.
Eriksson J B
This study describes how the air quality in a displacement ventilated classroom can beinfluenced by the position of a contaminating person, and by the activity of a person who walksaround in the room.
Mattsson M
Ventilation systems with heat recovery offer several advantages such as, of course, energy savings but also the possibility to add acoustic and filtration treatment.
Bernard A M, Lemaire M C, Spennato B, Barles P
The paper describes the results of a Pan-European survey carried out on identifying thebarriers that restrict the implementation of natural or simple fan-assisted ventilation systems inthe design of new office-type buildings and in the refurbishme
Aggerholm S
This paper is concerned with heat and mass transfer through two typical staircases, The firststaircase connects the two individual floors of a two-storey building, and the other connectsthe three individual floors of a three-storey building.
Peppes A A, Santamouris M, Asimakopoulos D N
Today, the development of new technologies to improve building envelope performances ishighly encouraged and provides a clear challenge for designers and researchers. In thiscontext several typologies of active envelopes have become very popular.
Saelens D, Hens H
A systematic analysis of recently constructed dwellings in the Flemish Region has beenundertaken within the SENVIVV-project (1 995- 1998) [I]. In total 200 dwellings have beenexamined in detail.
Bossaer A, Demeester J, Wouters P, Vandermarke B, Vangroenweghe W
In many existing ventilation systems unintentional reentrainment of pollutant, due to improper location of exhaust and air intake, decreases quality of indoor environment.
Sowa J
The emissions of building materials like volatile organic compounds and indoor airbornecontaminants such as environmental tobacco smoke expose occupants to hazardowsubstances.
Takemasa Y, Moser A

Pages