Airtightness - before and after pressure tests demonstrate residential retrofit results.

Presents pressure tests pre and post retrofit for several groups of North American houses which have been sealed to reduce air leakage. This summarizes research carried out in Canada and the USA over the last few years. Briefly discusses test procedures used.

Component leakage values and their relationship to air infiltration.

Reviews recent research in residential infiltration with an analysis of how the results are utilized in the design-build process. Identifies component testing as the research area most applicable to practical application efforts. Provides component and assembly test data. Discusses the need to reorient certain research efforts to more practically meet the needs of the residential industry. Presents clarifications and extensions of recently published work on component leakge.

Air curtain installations

Deals with the problems of open building passages and tunnel like entrances caused by thermal influences and wind currents. Shows advantages of air screening, especially where high pressure differences occur.

Air quality control strategies for health, comfort, and energy efficiency

Within the last ten years, energy shortages, economic pressures, and changes in indoor environmental requirements have resulted in buildings that are more energy efficient but less forgiving, environmentally. These results indicate that energ

Recent indoor air quality research in the US.

Gives a brief review of recent indoor air quality research in the USA, including instrumentation, monitoring health effects and remedial action.

Air flow calibration of building pressurization devices.

Describes a calibration technique to relate the air flow rate through a blower door to the fan speed and pressure difference across the door. To obtain an accurate and well-documented calibration of pressurization devices, a facility was designed and constructed at the US National Bureau of Standards. This accurately determines the flow rate through the fan as a function of fan speed, air density and pressure difference across the fan.

Program for hand-held computer estimating energy savings from reinsulating houses.

Describes a program which enables a hand-held computer to perform the energy audit calculations used in Building Practice Note No.20 "Estimating energy savings from reinsulating houses". The computer prompts the user for information, and provides a fast and versatile way of performing energy audit calculations.

Different tracer gas methods for assessing air quality - compilation of experimental data.

Continues on from a previous paper, which gives a theoretical framework for using moments of concentration histories as a means of assessing air quality. Gives a more detailed presentation of the test conditions and the results from each test, together with plots of concentration v.time graphs.

A detailed investigation of the air infiltration characteristics of two houses.

Describes a 2 year study sponsored by EPRI to ivestigate relationships between energy use, air infiltration and indoor air quality. Uses 2 bi-level, detached houses, identical in design and wind exposure. Continuously monitors parameters related to related to energy use, air infiltration, and indoor air quality.

Wind and infiltration interaction for small buildings.

Describes a model that predicts air infiltration from both wind and temperature influence to within 20%. Compares the predicted value and measured infiltration from a full-scale test structure, revealing an average discrepancy of less than 10 m3/hr (out of an average of approx 150 m3/hr). Presents direct measurements of the wind velocity and pressure coefficients induced by the wind on the full-scale test structure.