Operation of passive stack systems in summer.

The ventilation rate in a building depends on many things, one of which is the air temperature. The air temperature in turn depends in part on the ventilation rate. The effects of this relationship are generally overlooked in both thermal and ventilation models. To study this effect a model has been developed which integrates the models GAINE and SILONA developed at CSTB. This allows the prediction of the natural ventilation rates caused by the actual temperatures in the building.

Indoor ozone concentrations: ventilation rate impacts and mechanisms of outdoor concentration attenuation.

The classification of outdoor (ambient) air as fresh for the purposes of ventilation is not always appropriate, particularly in urban areas. In many cities of the world, urban air frequently violates health-based air quality standards due to high ozone concentrations. The degree of protection from exposure to ozone offered by the indoor environment depends on the relationship between indoor and outdoor ozone levels. Existing concentration data indicates that indoor/outdoor ozone ratios range between 10 and 80%.

Correction of tracer gas measurement results for climatic factors.

This paper deals with the problem of the weather influence on ventilation rate for naturally ventilated buildings with purpose provided openings and vertical shafts. Hitherto, it has not been possible to predict the ventilation rate or to extrapolate it for other weather conditions than the measured ones, without performing a heavy calculation exercise by means of running a computer program. In the paper a prediction as well as an extrapolation procedure is outlined . The procedures are based on generalised output data from a single zone infiltration and ventilation model (AIDA).

CMHC residential indoor air quality parametric study.

The purpose of this study was to carry out a mathematical modelling analysis of the effect of indoor pollutant source strengths and ventilation rates on the concentration of pollutants. These concentrations are then compared to various human exposure limits and targets. The modelling was carried out for a variety of ages of residential detached housing for a range of Canadian climatic conditions. Although a literature search was performed, pollutant source strength data for housing was not generally available.

A new ventilation strategy for humidity control in dwellings.

This report presents the results from the registration throughout a month of relative humidity, temperature and outdoor air exchange as well as the concentration of carbon dioxide in each room of an inhabited single family house, in which all rooms are ventilated by a mechanical balanced ventilation system with variable air volume. The outdoor air rate is controlled by the relative humidity, which is kept on a value adequate to reduce the living conditions for house dust mites and prevent condensation on the indoor surfaces of the building.

Ventilation criteria, effectiveness, measurement.

           

Pages