The key to persistence.

To Russia with blower doors.

Feasibility of ventilation heat recovery in retrofitting multi family buildings.

The work concentrated on estimating the effects of building leakages and terrain parameters on the air infiltration. The analysis was performed mainly using a multi zone airflow model Movecomp with which the building and its ventilation system could be described in detail. The computations were performed for a flat in a 418-storey building. The highest infiltration occurred in an untight two-facade flat in open terrain. The calculations gave valuable information on the effect of the location of the leakage.

Design and installation of passive stack ventilation in retrofitted apartment buildings.

Almost 60% of French residential buildings were built before the seventies, and an important part of those is to be retrofitted for complying with new needs with regard to acoustic insulation and energy saving. Retrofitting modifies the airtightness of the building envelope and can lead to an insufficient air change rate in passive stack ventilated buildings ; the existing ventilation system has therefore to be redesigned in order to insure adequate indoor air quality.

The effectiveness of housewrap.

Pages