Energetic effects of demand - controlled ventilation retrofitting in a biochemical laboratory building

The main objective of the demonstration project LabSan is the innovative energetic retrofitting of a research laboratory building (3724 m² net floor area) which can serve as an outstanding and guiding example for a large number of existing laboratory buil

Blower door tests (EN 13829) for quality assurance : getting air-tight buildings in retroffiting, too

For retrofitting as well as for new buildings a good airtightness is an important issue. In Germany, Austria and Switzerland about 1000 persons conduct blower door tests according to EN 13829 in order to characterize the air permeability of buildings. Also, preliminary measurements of the air barrier are made, often by the craftsmen themselves. Early measurements allow to repair leakages more easily than when the building is completed.

Ventilation retrofitting of public office buildings in Greece

This paper presents aspects of an office renovation project of the Social Insurance Institute (SII), the largest Social Security Organization in Greece. The project refers to small and larger SII office buildings, including various stages of intervention, ranging from the construction of new buildings, to renovation of existing buildings. Construction and electro-mechanical studies for each building were carried out in order to implement the appropriate and feasible actions.

Low energy cooling techniques for retrofitted office buildings in central Europe

Until the 1970’s most office buildings in central Europe were not equipped with mechanical cooling (airconditioning). Due to increasing requirements for thermal comfort and warmer summers, nowadays mechanical cooling is often applied to such buildings, ho

Air leakiness of non-standard housing : impact of upgrading measures

Sheffield City Council in the UK identified some dwellings of non-standard construction that needed to be refurbished. The refurbishment mainly involved applying insulation and rendering to the exterior surfaces of external walls and replacing old windows. The main aims of the refurbishment for the Council were to improve the condition and appearance of the dwellings and reduce conductive heat loss through the fabric.

Estimating effects of moisture damage repairs on students' health - a long-term intervention study

The aim of that study that lasted 5 years was to assess the effect of repairs made to moisture-damaged school buildings on the students' health. With repeated questionnaires it was possible to compare the occurrences of symptoms before and after the repairs in school.

A Study of a Mixed Mode Environment in 25 Cellular Offices at the University of Sydney

Twenty five cellular offices in the Wilkinson Building at the University of Sydney, Australia are ventilated through operable windows and doors and have been retrofitted with a supplementary reverse cycle cooling/heating system with an occupant controlled fancoil unit in each room. Energy consumption and occupancy and temperature status of rooms have been monitored since the system was commissioned at the end of 1997.

IEA ECBCS Annex 36 : Energy Concept Adviser for Technical Retrofit Measures - An internet-based Tool on Information, Assessment and Concept Development of Energy-saving Retrofit Strategies

Research partners of 10 different countries are developing a computer tool in the framework of IEA ECBCS Annex 36, which helps decision makers to include the most energy-efficient and economic technical retrofit measures into the retrofit of their educational buildings.

Indoor air quality in retrofitting educational buildings

For historical and demographical reasons, in many European countries, an important part of educational building must be retrofitted. These retrofitting must be carried out in a context of reduction of greenhouse emissions and energy consumption.Among different targets for retrofitting, there are the improvement of indoor environment. In fact, educational buildings are particularly vulnerable to indoor environment problems. Studies have indicated a correlation between the way educational buildings are designed, or retrofitted, and student performance.

New european project on advanced concepts for SUstainable Building RETrofit (SUBURET)

The scope of the program SUBURET is to develop tools and design methods for advanced retrofit, to demonstrate successful retrofit concepts and to perform a technical and social evaluation.

Pages