Measurements of ventilation rates in houses with natural and mechanical ventilation systems

Describes measurements made to compare ventilation rates in six Belgian houses with both natural and mechanical ventilation systems using O2 and N2O as tracer gases. Ventilation rates were correlated with wind speed. Air leakage across individual components of the house was measured and from this the distribution of leakage areas calculated.

Determination of the ventilation rate in a series of social houses

Describes the determination of infiltration rates for houses in Seneffe. Gives infiltration rates for individual rooms, found using O2 as tracer gas, and recording wind speed and direction. Determines global air renewal rate using N2O as tracer gas, by injecting gas through ventilators into all rooms and measuring concentration in each room. Calculates global concentration from individual measurements.

An automated controlled-flow air infiltration measurement system.

Presents description of an automated, controlled-flow air infiltration measurement system. This system measures total air flow, a volume per unit time, due to infiltration in a test space. Data analysis is discussed and the mixing problem analysed. Different modes of operating the system are considered : (1) concentration decay, (2) continuous flow in a single chamber and (3) continuous flow in a multichamber enclosure. Problems associated with the use of nitrous oxide as a tracer gas are described.

Ventilation measurements in houses and the influence of wall ventilators.

Using nitrous oxide as a tracer, the author made 390 measurements of ventilation rates in seven closed rooms of six houses, in Melbourne, Australia. Half of the observations were taken when the wall ventilators were sealed, in order to explore their influence on room ventilation. Results for each room, grouped in ranges of wind direction and according to whether ventilators were open or closed, are shown as regression curveson plots of ventilation rate against wind speed. The ventilators are shown to have only a slight effect on ventilation.

Airtightness and ventilation Tathet och ventilation

Describes measurements of airtightness and ventilation in prefabricated 'modulent' houses, 25 single-storey with habitable lofts and 8 single-storey, all with mechanical extract systems. Measurements used pressure method and tracer gas in houses with different airtightness, types of window, windproofing and facing materials. Possibility of presetting ventilation terminals and fans to achieve recommended airflows was investigated. Treatsrelationship between wind, temperature and airtightness. Notes number of shortcomings in ventilation system discovered during investigation.

Air change rates in buildings. Byginingers luftskifte

Summarises results of research project comprising survey of air tightness and natural air change rates in various types of residential building. Briefly describes equipment for pressurization tests and tracer gas measurements. Compares properties, range of measurement and cost of 5 different tracer gases. Provides some results from measurements in 53 single family houses and 28 flats. 9 of tested dwellings had their tightness improved and supplementary measurements made.