Preliminary ventilation effectiveness measurements by a pulse tracer method.

Workers in 'white collar' jobs continue to complain about air-quality' problems. Although there is a growing commercial interest in the measurement of gaseous and solid pollutants, there is no information on the effectiveness of New Zealand office ventilation systems. A set of baseline data is necessary to develop an understanding of the effectiveness with which air is provided in office spaces. This paper describes the results of preliminary ventilation effectiveness measurements made in mechanically ventilated spaces using a pulse tracer gas method.

Climate-based analysis of residential ventilation systems.

A study has been undertaken to (1) evaluate airtightness in recent construction dwellings in New York State, (2) evaluate the effectiveness of various strategies in providing adequate ventilation, and (3) study the use of various ventilation options by residential builders and heating, ventilation and air-conditioning (HVAC) contractors.

Survey of mechanical ventilation systems in 30 low energy dwellings in Germany.

This paper shows preliminary results of 18 out of 30 inspected ventilation systems in low rise, low energy residential buildings. We propose a method for the assessment of energy efficiency of ventilation systems. The majority of the inspected exhaust systems fulfills the conditions for the demanded air flow rates and energy efficient operation. However, typically the distribution of airflows to the rooms of the supply zone is rather weather dependent due to insufficient airtightness of the buildings and large stack heights.

The mechanical ventilation of suspended timber floors for radon remediation - a simple analysis.

Mechanical ventilation of the underfloor space is one of the most effective ways of reducing radon levels in buildings with suspended timber floors. There is a question however whether this ventilation should be supply or extract, sometimes extract is more effective, soinetiines supply is inore effective. This report presents a simple analysis of the problem and suggests the hypothesis that the relative effectiveness of supply or extract ventilation to the underfloor space depends on the relative airtightness of the floor and the soil or oversite surface.

Case studies of passive stack ventilation systems in occupied dwellings.

A possible alternative to mechanical extract ventilation for kitchens and bathrooms is passive stack ventilation (PSV). BRE has carried out work on this type of system in a test house under controlled conditions. To find out how well they worked in practice, four occupied dwellings were monitored over a period of 2 - 3 weeks each. Each dwelling had two ventilation ducts. Air flow rates within the ventilation ducts were measured, together with humidities, temperatures and climatological data.

Air change effectiveness measurements in two modern office buildings

Local age of air and air change effectiveness were determined in two office buildings using tracer gas techniques to study the air applicability of the associated measurement procedures in mechanically ventilated office buildings. Measurement issues examined include the establishment of a uniform tracer gas concentration at the start of the test and the relationship of ventilation system configuration and system operation to the test procedure.

Airtight additions to the campus.

Two new halls of residence, designed by Rick Mather Associates, are currently under construction at the University of East Anglia. All 800 of the near-identical student rooms have en-suite, prefabricated bathrooms, designed to be craned into position. Their low energy design required high standards of air-tightness and that mechanical ventilation systems be threaded through the buildings.

Pages