Effects of outdoor air conditions on hybrid air conditioning based on task/ambient strategy with natural and mechanical ventilation in office buildings

The aim of this study is to clarify the effects of indoor environmental characteristics of hybrid - natural and mechanical - air conditioning systems in office buildings during intermediate seasons. The other objective was to obtain design data.

The influence of personality, measured by the Karolinska Scales of Personality (KSP), on symptoms among subjects in suspected sick buildings.

That research is based on the assumption that there are differences among normal subjects as to their vulnerability to stress-related symptoms to health/illnessThe study aims at increasing the understanding of SBS complaints in relation to personality factors.A relationship between personality characteristics and health-related behaviors, and between personality characteristics and perceived health is demonstrated.

Standard 62.2. and indoor polllutant sources

The author asserts that to maintain a good indoor air quality, both ventilation and reduction of the pollutants sources are necessary. Standard 62.2 defines the minimum requirements about ventilation for an acceptable indoor air quality, but does not deal directly with the sources of pollutants. So the author gives an inventory of the main indoor air pollutants and how to cope with them. He maintains that the treatment of the pollutants at their source is very often the best way to keep a good indoor air quality.

Application of a simple method for detecting and quantifying VOC sources

The sick house syndrome has become a serious problem in Japan recently. It is important tospecify and quantify the source of chemical pollution. In this study, passive samplers for concentration of chemical substances in the air, ADSEC for emission rate of chemical substances from building materials and PFT method for ventilation rate in a room were developed. These passive methods enable investigation of many houses at a time. Indoor air quality of a newly built house was measured by these passive methods in summer and winter.

Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility

The method of exposure prediction using the scales of accessibility of supplied air (ASA) and the scales of accessibility of contaminant source (ACS) is presented in this paper. The spreading performance of supplied air and indoor pollutants can be figured out by CFD simulation and then used for the prediction of contaminant dispersion. For the validation of the model, a traver gas measurement was conducted.

Contribution of indoor exposed massive wood to a good indoor climate : in situ measurement campaign

The aim of the study is to evaluate the possibility of ensuring an indoor climate within an acceptable range thanks to the use of large exposed massive wood surfaces. The description of the experimental study performed in four occupied flats of a multi-storey residential building in Sweden is made in this paper along .The analysis of the in-situ recordings is presented too.

Enhancement of ventilation performance of a residential split-system airconditioning unit

The design of ventilation performance of air-conditioning systems in residential buildings is not quite established. In this paper findings from a recent study of the ventilation performance and IAQ in a master bedroom in Singapore are presented. The need to design for ventilation provision in split system air-conditioning units is suggested by the findings.

On the study of a sick building : the case of Athens Air Traffic Control Tower

Sick syndrome episodes were reported by the employees of Athens Air Traffic Control Tower (ATCT). In this study recent indoor air quality measurements made in ATCT are presented and discussed. The data indicated that VOCs concentrations were above outdoor levels in certain places of the building, some actions were taken to improve the indoor environment and afterwards a second set of measurements were made, inside and outsite the ATCT building : the results indicated an improvement of the indoor air quality.

62.1-2004 offers revised ventilation rate procedure

This paper presents the latest edition of the standard 62.1. It combines the 62.2001 version with 17 approved addenda, all of them have been approved by both Ashrae and ANSI. The most significant changes involved the ventilation rate procedure, minimum ventilation rate table and outdoor air treatment requirements.
That document is easy to use for designers, code officials and others users .
That standard is continuously reviewed and revised through addenda to keep up with new research findings and experience from the field.

A pilot study using scripted ventilation conditions to identify key factors affecting indoor pollutant concentratiion and air exchange rate in a residence

This paper describes a pilot study conducted in an occupied family house in Ohio to determine if a script-based protocol could be used to obtain data useful for the identification of the key factors affecting air-exchange rate (AER) and the relationship between indoor and outdoor concentrations of selected traffic-related air pollutants.