A standard for minimum ventilation.

The air infiltration associated with ventilation in buildings is recognized in ASHRAE Standard 62-1981, Ventilation for Acceptable Indoor Air Quality. In the light of recent trends toward increasingly tight housing, which limits air infiltration for ventilation, dependence on this source of outside air is onepoint that must be carefully considered in the Revised Standard. Other points to be considered are ventilation efficiency, necessary dilution of particulates and other pollutants, and how changes in humidity, air temperature and local heating may alter pollution levels in buildings.

Air infiltration. Where we stand today. Outlook. Zusammenfassung. Wo stehen wir heute. Ausblick.

Briefly notes the significance of ventilation heat losses for energy consumption. Notes the main sources of air pollutants in indoor air and the recommended fresh air rates per person for housing, for smokers and non-smokers. Notes the need for a well-sealed facade with mechanical ventilation and for judicious facade leakiness in the absence of mechanical ventilation. Notes the long-term need is for improved control of air infiltration. Notes briefly the AIC publication "Air infiltration control in housing".

Multivariate model for predicting NO2 levels in residences based upon sources and source use

Diffusion-type passive monitors were placed for a two-week period in each of 303 residences in the New Haven (Conn.) area during a 12 week sampling period January to April 1983. For each home NO2 levels were recorded outdoors, and in three ro

Computer analysis of building ventilation and heating problems

This paper presents a mathematical model, implemented in a general computer code, that can provide detailed information on the velocity and temperature fields prevailing in three-dimensional buildings of any geometrical complexity, for a given v

Case study of a sick building

Demonstrates that complaints by office staff about their physical environment are not necessarily caused by physical deficiencies. Trying to reduce the level of complaints by adjusting heating ventilating and air conditioning (HVAC) systems can therefore be an unrewarding task. Greater attention needs to be placed on - communications between management, those responsible for running HVAC systems and staff. Staff need the feeling that they can influence, if not control, their environment. Staff should also have more realistic expectations about their thermal comfort.

An office environment - problems and improvements

The employees in a large office in Trondheim were complaining about headache, tiredness, sickness, allergic reactions in eye and nose, dry skin, respiratory diseases etc., and as usual they believed that their inconvenience was due tothe ventilating system. However, preliminary investigations did not verify this assumption, although it was evident that the heating and ventilating system was part of the problems. Measures included reduction of room temperature, antistatic treatment of carpets, and replacement of noisy ceiling diffusers.

HVAC system operational parameters affect airborne fungal levels in occupied spaces

The National Institute for Occupational Safety and Health (NIOSH) and the U.S. Army, Construction Engineering Research Laboratory (USA-CERL) have collaborated on a project that examines the influence of heating, ventilation, and air-conditioning (HVAC) system operational parameters on the levels of microorganisms found in a simulated office space. In these experiments, fungi were collected as representative microorganisms using side-by-side sieve and slit samplers. Experiments at USA-CERL demonstrated that fan coil units are a major source of fungal aerosols in the built environment.

Use of vegetation to ameliorate building microclimates

Evaluates the space-conditioning energy conservation potentials of landscapes designed to ameliorate building microclimates. The physical bases for vegetative modifications of climate are discussed, and results of past study of the effects of vegetation on space-conditioning energy consumption in buildings are reviewed. The state-of-the-art of energy-conserving landscape designs is assessed and recommendations are presented for further research. Landscaping mobile houses and single family dwellings is considered.

Indoor air pollution - Some Canadian experiences

It is only recently that indoor air pollution has begun to attract the attention it deserves in Canadian Governmental and Building code circles. Two main events have been catalytic towards this increased emphasis. First, the ban on the use of ur

Air quality measurements in low leakage houses

Results of air quality measurements are presented for a group of low-leakage houses located in Saskatoon, Saskatchewan. A total of 46 houses were tested for formaldehyde, nitrogen dioxide, radon, and humidity levels. The median level of formalde