Submitted by Maria.Kapsalaki on Wed, 01/29/2020 - 14:31
Due to the wind induced pressure, different results may be obtained if the inside-outside pressure difference is measured across different locations on the building envelope, i.e. if the external pressure tap of a differential pressure sensor measuring this pressure difference is placed in different positions. Therefore, the position of the external pressure tap may influence an airtightness test result as well.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 15:45
Excessive air leakage through the building envelope increases the infiltration heat loss and therefore lowers the energy efficiency. Therefore, very good airtightness is required in case of well insulated buildings equipped with a mechanical ventilation system with heat recovery (e.g. n50 < 0.6 h-1 for passive houses). Although the building industry has progressively adopted strategies to comply with such strict limits, it is still important to study how and how much the airtightness influences the energy efficiency of different types of buildings in different climatic conditions.