Strategies for the planning and implementation of airtightness on existing sloped roofs

A project at the Energie- und Umweltzentrum (e.u.[z].) Springe looked into strategies how insulation and sealing components can be installed in existing constructions to improve the best airtightness.

Optimal positioning of air-exhaust openings in an operating room based on recovery test: a numerical study

This study investigates the influence of outlet location on conventional, turbulent-mixing operating-room (OR) ventilation performance. This was done by numerical simulation using computational fluid dynamics. Multiple configurations of OR outlets, both at floor and ceiling level, were examined, and the results were compared. OR ventilation-system performance in each case was examined by conducting a tracer-recovery test. Two common anesthetic gases, halothane (C2HBrClF3) and desflurane (C3H2F6O), were used to perform the test.

CFD simulation of an office heated by a ceiling mounted diffuser

The paper investigates the possibility for using a traditional ventilation system with ceiling mounted diffusers to provide heating under winter time conditions in relatively cold climates – in buildings with low transmition losses such as “passive houses”. The analysis is done through a number of CFD simulations of a simplified office. It is shown that even small over-temperatures reduce the Air Change Efficiency substantially. On the other hand even very small internal heat sources increase the efficiency.

Simulation analysis for indoor temperature increase and reduction of heating load in the detached house with buoyancy ventilated wall in winter

Detached residential wooden houses are a common type of housing in Japan. Decay of wooden components within the walls is easily caused by condensation or defective flushing. To solve this problem, a double-skin system with a room-side air gap was developed. In this system, during winter, the airflow in the ventilated wall circulates freely around the whole house. Therefore, during daytime, the airflow moves solar heat to base, and releases heat to the house at night which can increase indoor temperature.

Development of a decentralized and compact comfort ventilation system with highly efficient heat recovery for the minimal invasive refurbishment of buildings

To ensure adequate indoor air quality, ventilation is necessary in new constructions as well as in modernized existing buildings. In order to minimize energy losses, ventilation systems with integrated heat recovery should be used. Particularly in building refurbishment, ventilation systems need to be designed as compact as possible, to allow a subsequent integration in the existing building stock. Ventilation systems in which one component is responsible for ventilation and simultaneously for heat recovery are well suited for this application area.

Measured moisture buffering and latent heat capacities in CLT test houses

This research investigates the significance of the moisture buffering and latent heat capacities in exposed cross-laminated timber (CLT) walls with the respect to indoor climate and energy consumption. Hygroscopic materials have the ability to accumulate and release moisture due to change in the surrounding humidity. The moisture buffer capacity is regarded as this ability to moderate, or buffer, the indoor humidity variations. Latent heat refers to the heat of sorption due to the phase change from vapour to bound water in the material and the other way around.

Numerical simulation of indoor air quality - mechanical ventilation system supplied periodically vs. natural ventilation

Building integrated renewable energy sources e.g. photovoltaic system is one of the promised solution for improving energy efficiency in building. However such kind of the system is restrained by irregular power supplied and necessity to convert current from direct to altering form. Therefore, very often the electrical energy generated by photovoltaic system cannot be effectively utilised to supply building devices, e.g. components of HVAC or lighting system.

Optimization of data center chilled water cooling system according to annual power consumption criterion

The paper presents optimization model of the chilled water based data center cooling system. The optimization procedure includes system technological and mathematical model, limiting conditions and optimization criterion, which in this case is annual power consumption minimum. The cooling system model is defined by constant parameters and decision variables and consists of aircooled chiller, independent external freecooling heat exchanger (drycooler), computer room air handling unit (CRAH) and constant flow chilled water system with circulation pump.

Seasonal variation in airtightness

Airtightness of buildings is necessary to obtain healthy, sustainable and energy efficient buildings. Measuring the airtightness of a building has become more common lately, much due to the higher energy use in leaky buildings. The airtightness of a building can for example be measured in order to attain a certification, or on demand from a developer. In some studies, there have been large seasonal variations in airtightness. In most cases, the buildings are more leaky in wintertime, but there are also some investigations that show the opposite.

Multi-zone demand-controlled ventilation in residential buildings: An experimental case study

Numerous studies have investigated the application of multi-zone demand-controlled ventilation for office buildings. However, although Swedish regulations allow ventilation rates in residential buildings to be decreased by 70 % during non-occupancy, this system is not very common in the sector. The main focus of the present study was to experimentally investigate the indoor air quality and energy consumption when using multi-zone demand-controlled ventilation in a residential building. The building studied was located in Borlänge, Sweden.