Solar Thermal and Electric Desiccant Cooling System,Part 2: Experimental Investigation and Evaluation

The combined solar thermal and electricdesiccant cooling system is designed, fabricated,assembled and installed in the Laboratory ofBuilding Environmental Engineering of TohokuUniversity. The performance of the combinedsystem was observed and calculated. Theperformance of the whole system, thermalenergy system and desiccant cooling system ispresented in Part I of this paper.

Quantifying the performance of a top down natural ventilation windcatcher

Measurements and smoke tests show that thequadrants of a Windcatcher with a positivepressure across them act as supply ducts, whilethose with a negative pressure across them actas exhaust ducts.

On the Relation Between the Energy and Social Characteristicsof the Residential Sector.

Social, financial, energy and technical data from about 1 1 10 households have been collected during 2004 in the major Athens area. The sample has been divided in seven inconie groups and a detailed analysis has been performed. Iniportant conclusions have been drawn regarding the quality of households, the operational conditions and the energy spent per income group. Low income people are more likely to be living in old buildings with poor envelope conditions. The cost per person and unit area is much higher for the low income group for both heating and electricity.

Study on Airflow around Building Roof for Design of Natural Ventilationby Chimney-Part2 Wind Velocity Distribution above Building Roof-

The purpose of this study is to clarify thecharacteristics of airflow around building roofand to provide the guidelines for design ofnatural ventilation by chimney.

Displacement Ventilation System with Radiation Panel for Sickroom-Influence of Radiation Panel on Contaminant Concentration Profile -

For the patient, the sickroom is a place for themedical treatment and is also the living spacewhere they spend almost all time in a day.Therefore, high indoor air quality and thermalcomfort are needed in the sickroom.We propose to use the displacement ventilationas a means of obtaining high indoor air quality,in combination with radiation panel forindividual control of thermal environment. Thisstudy is intended to examine the validity of thissystem. This paper describes the experimentaland calculated results on the influence ofradiation panel on contaminant concentrationprofile.

Design process for integrated concepts with responsive building elements

An integrated building concept is a prerequisiteto come to an energy efficient building with agood and healthy IAQ indoor comfort. A designprocess that defines the targets and boundaryconditions in the very first stage of the design and guarantees them until the building is finished and used is needed. The hard questionis however: how to make the right choice of thecombination of individual measures frombuilding components and building sewiceselements.

The effect of thermal mass on the cooling load in dwellings in a moderate climate

To obtain thermal comfort in a moderateclimate, dwellings were traditionally providedwith a heating system, but few had coolingsystems.

Capture Efficiency and Indoor Thermal Environment inside Commercial Kitchen using Low Radiation Cooking Equipment with Concentrated Exhaust

In commercial ltitchen, a large amount ofheat and moisture as the effluence need to beremoved. Therefore, a large ventilation rate isneeded and energy consumption can be large incommercial kitchen. To improve kitchencondition, supply eficient oxygen and save theenergy, low radiation cooking equipments withconcentrated exhaust were developed. Thispaper summarizes laboratory investigation intothe effect of low radiation cooking equipmentwith concentrated exhaust on coimiercialltitchen condition.

Airtightness requirements for high performance buildings

International building legislation is setting stronger and stronger requirements for the energy performance of buildings. The most recent example is the Energy Performance of Buildings Directive in the European Union. The improved energy performance of buildings can't be achieved by additional insulation or more effective building systems only. A major influence factor on the energy quality is the ventilation technology and also the airtightness of the building.

Ventilation Performance of Residential Kitchen Range Hood- Capture Efficiency of Island Hood

An island hood, which is often installed in anisland kitchen, is an exhaust range hoodmounted on a ceiling independently. Thecapture efficiency of the island hood is obtainedby experiment and CFD analysis. Examinedparameters are heat input, exhaust airflow rate,mounting height of the hood, and withlwithout abaffle plate. The Experimental results indicatethat the effect of the baffle plate is achieved inthe case of large exhaust airflow rate or smallheat input. Results of CFD analysis are higherthan that of the experiment in the all cases.