Energy saving potentials of an 100% outdoor air system integrated with indirect and direct evaporative coolers for clean room

In general, HVAC systems for clean room facility are required significant energy to maintain the required indoor environment. Due to high air change rates, reducing operating energy consumptions has been the critical issue. The purpose of this paper is to investigate energy saving potentials of 100% outdoor air system integrated with indirect and direct evaporative coolers (IDECOAS) serving a clean room.

Thermal comfort and EPB in residential building: a commented case study in Ravenna, Italy

The aim of this paper is to investigate the relationship between Indoor Environmental Quality index (IEQ): thermal comfort index and indoor temperature trend in moderate thermal environments, in buildings that belong to the Class A with reference to the Energy Performance of Building Directive (EPBD). The work consists of the measurement of IEQ and energy efficiency in a residential building located in centre-north of Italy. The results of the measurements, as well as the PMV-PPD indexes are presented and commented.

Modeling a solar chimney for maximum solar irradiation and maximum airflow, for low latitude locations

Numerous researches have shown the possibility to enhance indoor natural ventilation in buildings by using inclined solar chimneys, although most of them usually include determining an optimum tilt for the absorber, considering an inclination angle between maximum solar irradiation and best stack height.

Developing winter residential demand response strategies for electric space heating

The objective of this paper is to present space heating strategies leading to a load reduction during critical periods on the grid but also taking into account the occupant thermal comfort in order to make them acceptable. Using TRNSYS, three types of strategies were investigated: lowering the thermostat setpoint, storing heat in the building thermal mass during off-peak hours and lowering the setpoint during critical periods, and limiting the available power to baseboards.

Disaggregating primary electricity consumption for office buildings in Nigeria

This paper presents the findings of an investigation of electricity consumption in mechanically cooled Nigerian office buildings.  

A system for the comparison of tools for the simulation of water-based radiant heating and cooling systems

Low temperature heating and high temperature cool-ing systems such as thermally activated building sys-tems (TABS) offer the chance to use low exergy sources, which can be very beneficial financially as well as ecologically when using renewable energy sources.The above has led to a considerable increase of water based radiant systems in modern buildings and a need for reliable simulation tools to predict the indoor envi-ronment and energy performance.This paper describes the comparison of the building simulation tools IDA ICE, IES VE, EnergyPlus and TRNSYS.

Simulation of thermal comfort in soccer stadia using TRNSYS 17

The Soccer World Cup in Qatar 2022 has started a discussion on thermal comfort in soccer stadia, particularly in hot and humid climates and their related energy consumption.  To evaluate the thermal comfort in such an environment a calculation algorithm for the so-called “perceived temperature” (PT), is incorporated into the TRNSYS 17 simulation package.

A feasibility study of natural ventilation in a midrise student dormitory building

This study investigates the feasibility of utilizing natural ventilation through operable windows to provide ventilation and summer cooling for an existing university dormitory building in marine west coastal climate (warm summer and mild winter). A hybrid research approach is used to evaluate the performance of proposed natural ventilation schemes, featuring building energy modeling with fully integrated airflow network, onsite blower door tests, and building utility data analysis. Both ventilation and thermal comfort are studied during the investigation.

CFD modelling for swirl diffuser and its implications on air change effectiveness assessment to green star's IEQ-2

Swirl diffusers can create better air mixing to enhance indoor air quality and help achieve compliance with Green Star IEQ-2 through Air Change Effectiveness (ACE) measure but the lack of modelling guidelines gives rise to the use of various modelling approaches with different results. The ACE calculation depends strongly on the flow characteristics produced by the diffuser outlet that vary considerably between different modelling set ups.

The role of MVD in defining curtain wall system for energy analysis

Model based exchange has the potential to improve the process of information exchange between different disciplines (Eastman, 2006), such as architect and engineer. However, there has not been a lot of success in automating the process of acquiring building geometry for energy analysis. This paper is part of a PhD research that investigates ways to improve the efficiency of exchanging building geometry for energy analysis.