International Journal of Ventilation, Volume 6, 2007-2008

Volume content

Enter a comma separated list of user names.
Night cooling is promoted worldwide as an effective tool to reduce refrigerative cooling demand.
Pollet I and Renson P.
In France there is an increasing demand for energy efficient and environmentally friendly buildings of high thermal comfort.
Chlela F., Husaunndee A., Riederer P., Inard C.
The purpose of this work is to present a study of the indoor environmental conditions of an office which is fully occupied and naturally ventilated by window and door opening.
Assimakopoulos VD, Stathopoulou OI, Halios C and Helmis CG.
Sustainable architecture design for tropical climates requires the use of natural ventilation combined with other strategies including: the use of appropriate materials, site location, orientation of faades and solar shading, etc.
Gonçalves Bastos L.E., Barroso-Krause C.
Cross ventilation to reduce cooling energy is one of the most important techniques for maintaining acomfortable indoor environment in hot and mild seasons.
Shigeki Nishizawa, Takao Sawachi, Ken-ichi. Narita, Nobuyoshi Kiyota, Hironao Seto
The present study investigates the effect of alteration in the building shape due to some common remodelling practice on the wind pressure differences delta-p for cross-ventilation of a semi-detached low-rise building using Computational Fluid Dyn
Cheng See Yuan
Several studies have suggested that recommended ventilation rates are not being met within schools.
Coley D.A.,Greeves R, Saxby B.K.
The present study is focused on the relation between wind speed and air temperature during the summer period over the greater Athens area.
Papanikolaou NM , Livada I, Santamouris M, and Niachou K.
Gas phase filters were installed within the air handling unit of a HVAC system feeding 100 % fresh(outdoor) air to an office building.
Ginestet A., Pugnet D.
The natural ventilation of a building, flanked by others forming urban canyons and driven by the combined forces of wind and thermal buoyancy, has been studied experimentally at small scale.
Syrios K., Hunt G. R.
Full-scale experimental and computational fluid dynamics (CFD) methods were used to investigate the velocity and temperature fields in a mechanically ventilated room.
Kuznik F., Rusaouen G., Brau J.
This paper is not a technical paper but, instead, focuses on the methods by which information on recent advances in ventilation technology and systems may be transferred to engineers.
Kolokotroni M., Shilliday J., Liddament M., Santamouris M., Farrou I., Seppanen O, Brown R., Parker J., Guarracino G.
The requirements for good indoor air quality and energy efficiency have often been considered to be in conflict with each other.
Seppänen O.

Pages