International Building Simulation Conference 2003, Eindhoven, Netherlands.

Contains 190 papers.

Volume content

Enter a comma separated list of user names.
Whole building simulation may play a key role in the optimization and assessment of the market potential of new building components.
Vítor Leal, Eduardo Maldonado, Evyatar Erell and Yair Etzion
The barriers to simulation deployment in design practice are well documented.
McElroy L. B., Elrick B. F., Grant R., Telfer S. D., Elliot G. A.
It is necessary for fire safety that in case of a flash-over situation, the windows in the outer skin would break very fast and before the windows in the inner façade would break, so that the model of Law is valid in which case the NEN 6068  could
Erik den Tonkelaar
Occupant responsive optimal control is developed for so called smart façade systems.
Cheol-Soo Park, Godfried Augenbroe, Nader Sadegh, Mate Thitisawat, Tahar Messadi
Hourly energy simulation  was used in combination with a life cycle assessment framework to model the environmental effects of energy consumption in buildings.
Ayat Osman and Robert Ries
This paper presents "Scythe and Sew", a software environment for analyzing lighting simulation data. It provides a spreadsheet like infrastructure for manipulating high-dimensional simulation results.
Osbert Feng, Quy Nguyen, Daniel Glaser, John Canny, Ellen Yi-Luen Do
Consoclim is a building energy simulation software package which aims to simplify the input data. The building is modelled by only one capacity and five resistances.
S. Roujol, E. Fleury, D. Marchio, J.R. Millet, P. Stabat
The    performances  of  air  conditioning  equipments, like heat pumps, chillers or air conditioners, derive not only from the operative thermal levels, but also from the building requirement trend which normally involves frequent reductions of t
Ernesto Bettanini, Alessio Gastaldello, Luigi Schibuola
The evaluation of shading devices is generally carried out using a sequence of shadow pattern images showing the progression of solar penetration for particular times of the day or year.
J. Mardaljevic
In this work two numerical models are presented. The first one simulates the buildings thermal response and evaluates the internal air quality, while the second one simulates the human and clothing thermal systems and calculates the thermal comfor
Eusébio Z. E. Conceição
This paper presents a simulation study employed for the optimization of the building envelope for a new university building located in Montreal (latitude 450N).
Athanassios Tzempelikos and Andreas K. Athienitis
The validation and development of turbulence models are still important issues  related to Computa- tional Fluid Dynamics for ventilation purposes. The present work continues the work initiated by (Voigt, 2002).
Lars Køllgaard Voigt, Jens Nørkær Sørensen, Jakob Martin Pedersen and Morten Brøns
Experimental studies in building energy usage and environmental analysis are very time consuming and expensive, and require sophisticated sensors and instrumentation techniques.
Pedro Dinis Gaspar, Rui F. Barroca and R.A. Pitarma
This  article  presents  a  one-dimensional  model  of spray vaporization that can be easily used in thermal performance simulations of buildings.
Antonio César S. Baptista da Silva, José A. Bellini da Cunha Neto, Roberto Lamberts
A web-based, non-expert daylighting analysis tool has been developed to support daylighting-related design decisions in peripheral private offices during an early design stage.
C. F. Reinhart, M. Morrison
Present  international  standard  for  thermal  comfort such as ASHRAE Standard 55 and ISO 7730 were developed to serve as a guideline for moderate thermal environments e.g. mechanically air- conditioned spaces [CEN ISO 1995].
Henry Feriadi, Wong Nyuk Hien
A   two-level   analysis   was   used   to   study   the economic potential of implementing Building Cooling, Heating and Power (BCHP) technologies in the U.S.
Marek Czachorski, Jaroslav Wurm
Four areas in Texas have been designated by the United States Environmental Protection Agency (EPA) as non-attainment areas because ozone levels exceed the NAAQS1  maximum allowable limits.
Jeff S. Haberl, Piljae Im, Charles Culp, Bahman Yazdani, Tom Fitzpatrick, Dan Turner, Malcolm Verdict
Since buildings have a predominant impact on the global climate change and other  environmental issues, it has become necessary to consider environmental performance in building design.
Weimin Wang, Hugues Rivard, Radu G. Zmeureanu
The   sky   view   factor   indicates   the   relationship between the visible area of the sky and the area covered by urban structures.
Léa C.L.Souza, Daniel S. Rodrigues, José F.G. Mendes