The purpose of this study is designing a hybrid system which is a combination of radiant cooling and low temperature air conditioning integrated with ice stor- age system.
IBPSA 1999 - Kyoto, Japan
International Building Simulation Conference 1999, Kyoto, Japan.
Contains 177 papers
Volume content
This article presents the SIM-FAST software : it is a tool which allows to evaluate the energy consumption and the financial cost of French buildings in the Residential sector.
Load prediction for aptimal thermal storage: comparison of three kinds of model application | 1999 | English
It is necessary to predict the load of the following day and hours to establish optimal thermal storage.
The Simulation Problem Analysis and Research Kernel (SPARK) uses graph-theoretic techniques to match equations to variables and build computational graphs, yielding solution sequences indicated by needed data flow.
Simulation of ventilation and indoor air quality in houses using average japanese daily schedule | 1999 | English
In order to explain the effect of ventilation systems and airtight performance of houses in detached houses, the investigation was made on a simulation program which calculates the ventilation rates and indoor air quality.
In this article, we present the dynamic modelling of a heating and air conditioning small output installation in a residential building. The main aim of this modelling study is to acquire a better knowledge of all phenomena which govern the behavi
The operation of technical building devices demands a lot of heating, cooling and electric energy. This also causes monetary costs and pollutant emission as well.
This paper presents a mathematical model yielding a simplified representation of the thermal behaviors of ivy-covered walls. The model is integrated with a CFD program to implement simulation.
In this paper a new method called TSM was presented to analyze wind effect on high-density building areas. With TSM, a software named WEATHER is developed based on STACH-3.
This paper proposes useful techniques of regression analysis to estimate regional water temperatures for the optimum design of the hot water supply system.
Simulation of cleaning is a new area in building simulations. To make rational cleaning is it important to know how difficult it is to clean rooms. I define a Cleaning Index (CI) as the cleaning area divided by the floor area.
A model for the design of urban grids and fabric with solar rights consideration taken into account is presented.
The optimal supervisory control strategy for a central chilled water facility has been determined. A quadratic linear regression relation for the total system power in terms of the controlled and uncontrolled variables was developed using simula
Study on adaptive mesh generation method in CFD calculation with conjugate heat transfer model | 1999 | English
In order to make proper radiative meshes with considering thermal distribution on solid surfaces, we inves- tigated the adaptive mesh generation method and per- formed parametric survey for a threshold which con- trols subdivision of mesh.
Numerical analysis of air temperature increases in urban area using the building-urban-soil simultaneous simulation model | 1999 | English
The authors propose a predicting methodology combined with simultaneous solution for Building- Urban-Soil system to analyze the heat island phenomenon quantitatively in this paper. Using this model, numerical simulation is performed in order
Project REED (Residential Energy Efficiency Design) is a Web-based building performance simulation tool developed under contract to one of the nations largest utilities, to help their 4.5 million ratepayers make en- ergy efficient design decisions
An integrated simulation system for the building services design and facilities management purposes is being developed by Olof Granlund Oy.
Modeling and calibration of lateral heat loss rate in measuring the R value of partly heated wall | 1999 | English
An experimental apparatus (in-situ thermal test unit) and an analysis method have been developed for evaluating the thermal resistance of the building envelope on site.
Simulation of visual context in architecture, the environment that surrounds both building and observer, is an essential but problematic feature of realistic imagery.
Based on K- two equation turbulence model, we used PHOENICS 1.4 and numerically simulated air distribution and contamination field under different conditions in a vector- flow clean room.