The 17th AIVC Conference - Optimum Ventilation and Air Flow Control in Buildings, was held in Gothenburg, Sweden, 17-20 September 1996.

Contains 62 papers.

Volume content

Enter a comma separated list of user names.
This paper reports on the use of BRE's domestic ventilation model, BREVENT, to predict subfloor and whole house ventilation rates in a BRE/DoE test house.
Hartless R P
Since 1985 more than 170 very low energy houses, all of the same type and structure, were built in the Flemish Region, Belgium.
Pittomvils J, Hens H, van Bael F
Ventilation is necessary to provide a good indoor air quality to occupants in office buildings but is however a major energy consumer.
Ducarme D, Wouters P, Jardinier M, Jardinier L
Although the power law has been broadly accepted in measurement and air infiltration standards, and in many air infiltration calculation methods, the assumption that the power law is true over the range of pressures that a building envelope experi
Walker I S, Wilson D J, Sherman M H
Water use is distributed throughout building structures.
Campbell D P, Webb R S
The first part of the paper will show some aspects of experimental research on air distribution in ventilated rooms.
Cocora O
This paper reports on work carried out at BRE to address the need for guidance on designing for natural ventilation via single-sided and cross-ventilation in office spaces and the limits of application in terms of plan depth.
White M, Walker R
A Probabilistic model of air change rate in a single family house based on full-scale measurements has been developed.
Pietrzyk K, Handa K
Traditional air-handling unit (AHU) control systems link the position of the exhaust air damper, recirculation air damper, and outdoor air damper.
Seem J E, House J M
The use of local exhaust is considered to be the most effective way to control pollutant dispersion from intense sources, such as in kitchens, in toilets, as well as in copy machine rooms.
Niu J L, Burnett J, van der Kooi J, van der Ree H
This paper describes the ventilation analysis undertaken during the design of a new music centre for which it was desired to avoid the use of air conditioning and conventional ducted mechanical ventilation.
Cohen R R, Davies R M, Standeven M A
While the use of heat energy has decreased since the middle of the 1970's the use of electricity in the Swedish stock of commercial buildings has increased dramatically.
Nilson A, Hjalmarsson C, Uppstrom R
Many dwellings with natural or gravity ventilation systems suffer from poor airchange rates. In Sweden, especially houses built in the 1960-ies and 1970-ies heated with electric resistance heating and thus without chimneys, are at risk.
Levin P
Full scale measurements of air flow velocities, temperature, intensity of turbulence and air exchange rate are carried out on two rooms with different types of ventilation located in the department of architecture at Chalmers University of Technol
Handa K, Pietrzyk K
Natural ventilation is being applied to an increasing number of new buildings to minimise reliance on mechanical ventilation and so reduce emission of greenhouse gases.
Riffat S B, Shao L
Wind towers (scoops situated on the roofs of buildings to catch the wind) have been in use for centuries in the Middle east and Pakistan, to provide ventilation and cooling with minimal mechanical plant.
Harris D J, Webb R S
Existing experimental techniques for calculating air flow through building cracks are usually based upon relationships derived from experimental studies employing relatively simple procedures.
Sharples S, Thompson D
Ventilation by displacement is a type of ventilation where the air flow is thermally driven.
Hansson P, Stymne H
Many modern buildings in the Nordic countries have mechanical ventilation. Passive stack ventilation is, however, an accepted ventilation system in the Nordic countries according to the current building codes.
Blomsterberg A
Train tunnels and subways are an interesting field of ventilation. Trains move air through tunnels at rates of 600 m³/s (over 2 x 10^6 m³ per hour) which is much more than flow rates in buildings.
Phaff H J C, de Gids W F