AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

The purpose of this study is to determine how levels of ventilation rates and indoor air quality vary in elementary schools in southern Japan. This study is based on field monitoring carried out as intermittent monitoring from summer to winter.
Iwashita G.
This study aims at investigating the actual conditions of indoor environment in schools in order toobtain fundamental information for proper ventilation design of buildings.
Yoshino H., Mihara K., Takizawa N., Kurabuchi T., Muramatsu S., Kumagai K., Noguchi M., Yanagisawa Y.
Air leakages can cause a significant energy penalty, inability of the heating system, and failure of the ventilation system – especially in passive houses. However, they can be avoided if given serious consideration in the design phase.
Dorschky S., Rolfsmeier S.
In the first phase of the current project, the ventilation rates of occupied houses in the northern region of Japan were investigated from 2001 to 2005.
Takaki R., Yoshino H., Mihara K. , Maatouk K.
Portugal has technical recommendations and standards regarding ventilation rates in naturalventilation systems.
Pinto M. , de Freitas V.P.,Stymne H., Boman C.A.
The Municipality of Imola is strongly committed to environmental friendly and energy consciouspolicies both at urban planning level and public building design.
Grosso M., Raimondo L., Dal Fiume A.
The amount of outdoor air ventilation in buildings is one of the most important determinants of indoor air quality, but many critical questions and misunderstandings exist.
Persily A.
Underfloor air distribution (UFAD) is a new method of supplying heated or cooled air throughout a building. Reported advantages of UFAD include energy savings and improved indoor air quality (IAQ).
Fisk W.J., Faulkner D., Sullivan D.P., Chao C., Wan M.P, Zagreus L., WebsterT.
The Local Dynamic Similarity Model (LDSM) is a ventilation model for predicting the discharge coefficient and the inflow angle at the opening of a cross-ventilated building.
Cheng-Hu Hu, Takashi Kurabuchi, Masaaki Ohba
Indoor microbial exposure has been implicated in various adverse health effects.
Su H.J.,Wu P.C., Chien H.P.
An underfloor ventilation system providing three different airflow patterns, a mixing ventilation system, and a displacement ventilation system utilizing a wall-based diffuser were tested in a mock-up of a typical office.
Cermak R., Melikov A.K
The objective of this study is to investigate how measured ventilation rates in dwellings vary over the heating season in a Nordic climate.
Stymne H., Emenius G., Boman C.A.
In this paper experimental results are used to verify and validate a computational fluid dynamics (CFD) model based on a commercial package. The validation is used to ensure that the CFD model is able to simulate stratum ventilation.
Lin Z., Chow T.T., Tsang C.F.
1. Thoughts 1. Why care? 2. Sustainable Architecture or just Architecture, are they something different? 3. On past and future – learning from tradition. 4. On the overwhelming power of design. 5. On starchitecture. 6.
Tombazis, A.N.
The utilization factor is a relative well-known concept used in some simplified calculation methodssuch as the procedure described in the CEN EN-13790 where the FU depends on the inertia of thezone.
Sanchez de la Flor, F.J.; Alvarez Dominguez, S.; Salmeron Lissen, J.M., Ruiz Pardo, A.
This paper presents a case study of a typically poor energy performing factory building singled outfrom nation-wide study on factory buildings for improving energy performance.
Chia, Y.L.; Lee, S.E.
To achieve the intended results of building, managing and using a property requires knowledge,continuity and communication, which can be assured by a dynamic and flexible quality assurance(QA) system.
Wahlström, A.; Törnström, T.; Ruud, S.
Since most important design decisions are taken during the first design phase, an evaluation ofthe total environmental impact is necessary at that moment.
Allacker, K.; De Troyer, F.
The goal of this study, carried out on a wooden building, is to apply the methodology of identification inorder to obtain the physical parameters which characterize the thermal behaviour of the building.
Mejri, O.; Palomo, E.; Ghrab-Morcos, N.
In this paper the thermal behaviour of a direct ground cooling system located in Milano, Italy, isstudied by means of dynamic simulations performed in the TRNSYS environment.
Angelotti, A.; Solaini, G.