A study on the identification and quantification of sources of VOC's in 5 air-conditioned Singapore office buildings

For that study a mass balanced model is applied to determine area-specific emissions rates in office buildings. Sources of VOCs were identified, put into 3 broad categories and quantified : building materials (23.7 %), ventilation systems (39.0 %) and occupants and their activities (37.3 %) .

Effect of internal partitioning on indoor air quality of rooms with mixing ventilation - basic study -

This paper sums up the results of a study on the internal partitioning with its effects on the room air quality along with the ventilation performance. Physical tests and numerical modeling for a CFD simulation were used to evaluate different test conditions that employed mixing ventilation from the ceiling.

Performance of ventilation system in a non-standard operating room

In Hong Kong, design and construction of new operating rooms and upgrading of older ones have been based on the UK Health Building Notes. In a case study, field measurements showed that the airflow and some design features did not tally with the specifed requirements.
As the risk of contamination in an operating room can be minimized through appropriate filtration and air distribution scheme, a CFD analysis was carried out with the simulation of the temperature distribution, airflow pattern and the contaminant dispersion.

New indoor environment chambers and field experiment offices for research on human comfort, health and productivity at moderate energy expenditure

The international center for indoor environment and energy, at the Technical University of Denmark has at its disposal 3 old and 9 new spaces for studying indoor environments and their incidence on human comfort, health, productivity at moderate energy demands. This paper describes those climate chambers, new laboratory and offices used for field experiments.

Induced ventilation of a one-story real-size building

In that study, induced ventilation is experimentally explored in a small well-insulated manufactured home, located in the northern edge of the Negev desert in Israel. Temperature monitoring was performed inside and outside the building in summer along with velocity measurements inside the building. The results show that with induced ventilation the air temperature inside the home is like the ambient temperature, whereas, when no openings, the temperature inside the manufactured home is higher than the ambient.

Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage

It is not easy to provide simultaneously thermal comfort, proper air quality, efficient energy consumption to building occupants. In this paper an alternative methodology of real-time determination of optimal indoor air condition for HVAC system to achieve those 3 requirements is presented. A 24 hours operating HVAC system of a single-story building was chosen as a case study.The experiment results obtained with the proposed methodology were better than those from a conventional approach.

The study of active stack effect to enhance natural ventilation using wind tunnel and computational fluid dynamics (CFD) simulations

The use of a combined methodology of wind tunnel experiments and CFD simulations in order to study the potential of using active stack to enhance natural ventilation in residential apartments in Singapore is demonstrated in this paper. Comparison between the results obtained from the experiments and those from the simulations has been made.

Thermal comfort for naturally ventilated houses in Indonesia

This paper presents an extensive field survey conducted in residential naturally ventilated buildings in Indonesia. The data gathered has been analyzed and revealed that the Predicted Mean Vote equation predicted a warmer thermal perception compared to what people really felt. Under hot and humid tropical climate, people in free-running buildings had a preference for cooler environment and for higher wind speed.

Design, monitoring and evaluation of a low energy office building with passive cooling by night ventilation

For that study, 12 office rooms of a "Solar Optimised Building" in Germany have been monitored. The data have been evaluated by a new method for analysis that deals with short and long term measurements and with building simulation. A comparison between monitored data and simulation of a building with passive cooling by night ventilation is made on a long period.

Energy in air-handling units - results of the AIRLESS European project.

In this paper the authors present the results of the European AIRLESS programme whose aim was to identify the pollution sources in air-handling units, and then avoid or eliminate this pollution. The authors propose several energy efficient ways to provide good indoor air and efficient indoor environment conditioning.