In this swedish report, an inventory and a multidisciplinary review (EUROWORKS) of the scientific literature about networks on indoor environmental quality and health is made. That work was performed during 2001 and was supported by the European Commission.
This document gives an overview of the work within the area of housing and health. It defines firstly what is healthy housing, then how housing impacts on health, and deals with a survey made in 8 cities in Europe.
The number of Underfloor air systems (UFAD) has incresed 40 % between 1995 and 2002, thanks to the benefits it offers : lower churn costs, improved IAQ, lower energy costs, potential to reduce floor-to-ceiling heights. But knowledge of how to apply the technology is not widespread.
Design phases, construction and commissioning phases of the UFAD project are presented along with a paragraph on the importance of educating building occupants on UFAD.
Supply air CO2 control (SACO2) is a technique for measuring the outdoor air fraction in the supply air and controlling the outdoor air intake. It is applicable to recirculating systems serving multiple places where ventilation targets are based on outdoor airflow rate per person. SACO2 offers significant benefits : energy savings, simple maintenance, adequate ventilation and ability to measure and record performance.
In this article, the sources of risk using DCV (demand control ventilation) are examined along with the components typically and the possible ways to minimize risk without sacrificing potential energy savings.
That addendum 62n modifies the ANSI/ASHRAE Standard 62 "Ventilation for Acceptable Indoor Air Quality, it contains an update to the minimum prescribed ventilation rates and includes ventilation airflow "additivity" for dilution of people-source and building source contaminants.
The aim of that study was to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Tests on ducts of 6, 8, 10 in. nominal diameters were conduted under different compression configurations following ANSI/ASHRAE standard 120-1999. That study suggests potential improvements to that standard and gives new data for duct design.
Microperforated sound absorbers have been successfully implemented in suspended ceilings, transparent panel absorbers or other applications. That principle of microperforation has been introduced to further engineering areas such as duct systems where the air flows through the micorperforation. So along with the ventilation aspects, the sound absorption effects need to be taken into account. In that aim, the theory of a microperforated absorber was extended by the effects due to airflow through the microperforation.
In this paper the complaint prediction model developed by Federspiel in 2000 is evaluated and recalibrated. Temperature time-series data and complaint data were collected from different size buildings from different geographical areas. Results are presented.