The paper describes the numerical simulation of a novel ventilation cooling system. The ultimate aimof the mathematical model is to facilitate the design of the system for specific buildings and climates.The model directly takes account of time dependency in that the diffusion equation for the heat flow inthe fabric of the room is solved. This approach means that important parameters (e.g. ventilationrates and internal heat gains) can be arbitrarily specified as functions of time.
Confined environments are indoor spaces which are not ventilated or few ventilated due to specific use (shelters, submarines …). In such environments, homogeneous and heterogeneous chemistry are expected to play a key role in indoor air quality (IAQ). The
The buildings sector offers the greatest potential for cost-effective reductions in greenhouse gasemissions out of all the sectors examined by the Intergovernmental Panel on Climate Change.However that potential was based purely on technical measures applied to existing buildings and newconstruction. It is becoming increasingly clear that non-technical options involving building occupantcomfort, culture and behaviour will also need to be implemented in order to stabilise atmosphericconcentrations of CO2 within a useful timeframe.
When a building is used only for intermittent occupancy, continuous operation of ventilation system isnot necessary for achieving good indoor air quality during the occupation periods. Such buildings havea great energy saving potential which is not harnessed enough yet. Indeed, energy loss can be avoidedby promoting natural means and managing mechanical ones.
In hot and humid climates, desiccant air-conditioning systems have been suggested as suitable forimproving Indoor Air Quality (IAQ). Generally as dehumidification devices, various types of silica gelrotor have been used to control humidity.
Recently, products of chemical reaction have been at issue as the topic of research on Indoor AirQuality. In this study, the emission mechanism of 2-ethyl-1-hexanol (2E1H) is studied. It has beenreported that 2E1H at high concentrations is measured in indoor air over the long term. The emissionmechanism for 2E1H is considered that water with high pH in concrete slabs and self-leveling sub-floormaterial reacts to di-2-ethylhexyl phthalate (DEHP) in PVC flooring and compounds containing the2-ethyl-1-hexyl group in the adhesive.
Architectural design is becoming each day a more complex process while it seeks to embrace thevarious aspects of sustainability. The way how the buildings are affected by their own shape andmaterials, how the urban environment is affected by it and how this will affect the building, becomes acritical issue of the design process for sustainable architecture. The architectural design processshould be dynamic and look holistically at all building technologies and systems, including the urbandimension.
District cooling system (DCS) is a mass-scale production of chilled water generated at a central andremote chiller plant. Through an underground piping network, the chilled water is delivered to serve agroup of consumer buildings in a district area. DCS can offer both economical and environmentalbenefits. Because of the substantial capital investment and running energy involved, an optimal designof the distribution piping network is one of the crucial factors for successful implementation of thedistrict cooling scheme.
University dormitory is a kind of representative building in which central heating is supplied. The rooms are in simple types and the students’ activity schedule is quite steady, which makes dormitory room to be an appropriate place for field survey. This
Due to a variety of influence factors, outside dry-bulb temperature takes on a systematic and randomfluctuation. If a deterministic model is used to forecast the dry-bulb temperature, the predicted resultoften has a rough accuracy. Neural network can learn the internal regularity of the sample data bysample training; therefore it has very much adaptability and advantage in the aspects of forecast.The influence factors of outside dry-bulb temperature exist difference in the daytime and the nighttime,which makes the fluctuant regularity of outside dry-bulb temperature inconsistent.