CFD ANALYSIS OF AIRFLOW CHARACTERISTICS IN OFFICE ROOM WITH TASK AIR-CONDITIONING AND NATURAL VENTILATION

The performance of indoor airflow for the office room with the hybrid air-conditioning system has beeninvestigated by means of CFD analysis. The hybrid air-conditioning system is composed of under floorair supply outlets for task zone and the natural ventilation openings for ambient zone. The measureddata (Kotani et al. 2006) at the office room in existence was used as the boundary condition of the flowrate of each natural ventilation opening and task flow outlets for CFD.

A STUDY OF SOLAR CONTROL FILM IN A HOTEL BUILDING

Energy tariff is a major cost in hotel operation. Effective use of energy can reduce operationalexpenditures and has important environmental benefits. Solar heat gain particularly throughfenestration, contributes to a significant proportion of the building envelope cooling load. More solarradiation means more total solar heat gain and hence, more cooling requirements and larger electricityconsumption for air-conditioning in hot summer. Daylight makes an interior space look more lively andattractive and people expect good natural lighting in their living spaces.

SKIES CLASSIFICATION USING ARTIFICIAL NEURAL NETWORKS (ANN) TECHNIQUES

In 2003, the International Commission on Illumination (CIE) adopted 15 standard skies that cover thewhole probable spectrum of usual skies found in the world. Each sky represents a unique distribution.Once the standard sky has been identified, the sky irradiance and outdoor illuminance at any surfacesof interest can be obtained for subsequent investigations and complicated expressions for inclinedsurface models are not required.

BEARING THE SUMMER HEAT IN URBAN OSAKA APARTMENTS: ANALYSIS BY AGE

A questionnaire survey of urban Osaka apartment residents elicited data related to the use of airconditioners, portals, and electric fans as means of bearing summer heat. Those means respectiverelationships to respondents attributes, especially age, were investigated. Results show the following:1) regarding electricity expense awareness, younger respondents (under 40 years old) save electricitymore (p

ENERGY DEMAND SCENARIOS FOR BUILDINGS AND THE INTERGOVEMMENTAL PANEL ON CLIMATE CHANGE’S FOURTH ASSESSMENT REPORT

This paper reviews the scenarios developed for the Intergovernmental Panel on Climate Change(IPCC) analysis. It pays particular attention to the applicability of these scenarios to the analysis ofenergy demand, energy savings, and reductions of CO2 emissions for the buildings sector.

RADIATIVE PERFORMANCE OF LOUVRES, SIMULATION AND EXAMPLES IN ASIAN ARCHITECTURE

For most sunny climates, the presence of high thermal loads due to the effect of solar radiationreinforces the need to protect the glazing in the facades and skylights. If this is not properly donethe performance of air-conditioning systems would be compromised and the lifespan of thatglazing would result severely affected. However, depending on the type and reflective nature ofthe shading system selected, undesirable effects for ventilation, comfort and especially forday-lighting tend to occur in the rooms provided with apertures that, paradoxically, we are trying toprotect.

ESTIMATING THE EFFECTS OF AMBIENT CONDITIONS AND AGING ON THE PERFORMANCE OF UVGI AIR CLEANERS

Ultraviolet germicidal irradiation (UVGI) uses UVC radiation produced by low pressure Hg vapor lampsto control biological air contaminants. Lamp UV output depends on multiple factors, includingaccumulated operating time (age) and the thermal effects of ambient air temperature and velocity.Additionally, the life of some lamp types depends on the frequency of on-off cycles.

THE COMBINATION OF FIRE EXTINGUISH SYSTEM AND LOCAL EXHAUST SYSTEM IN FUME HOOD

Working with volatile chemicals creates numerous hazards for scientists in laboratory. Therefore, it isrestricted to do such works in a fume hood, which is designed to draw fresh air from the room into thehood and then out into the ventilation system, in order to prevent the accidents happened.According to the laboratory fire incidents investigation, the authors observed that a fire occurred infume hood will be a serious problem which has the potential to get much worse in the future as moreand complex laboratories are used and as the hood usage density increase.

CONCENTRATION COMPARISON OF THE INDOOR AIR POLLUTANTS IDENTIFIED FROM THE RESTAURANTS WITH THE DIFFERENT COOKING AND VENTILATION METHODS

This study compared the concentrations of indoor air pollutants identified from the 5 restaurantsincluding a category A (two Korean barbecue houses) during a lunch time period and a category B(one Japanese, one Chinese, and one Italian restaurants) during a dinner time period.

INVESTIGATIONS OF GYPSUM BOARDS WITH REGARD TO THE MOISTURE-BUFFERING-EFFECTS

It is of significant importance that heat, humidity and air contents are well balanced in buildings, as animbalance of these factors may have a decisive effect on the construction as well as on the residents, forexample damage to the building structure, decrease of thermal comfort and increase of energyconsumption. Relative humidity, generated within the construction or in the interior of a building, is ofspecial importance. In recent times there is an increase in discussion and investigation on the influenceof humidity absorbing or desorbing surface layers in rooms.