STUDY ON PROPER DESIGN METHOD OF LOCATING WINDOWS AIMING AT UTILIZATION OF CROSS-VENTILATION IN DENSELY POPULATED URBAN AREA

This study is focused on the efficient use of cross-ventilation in a densely populated area by using roofwindows in particular. Wind tunnel experiments were conducted to understand not only the relationbetween the building coverage ratio and the coefficient of wind pressure (Cp) but also the relationbetween the roof slope of a residence and Cp value. To simulate an urban area, dummy models wereplaced around a target model, and the building densities were set to 0, 10, 20, and 40%. The roofslopes of residences were set to 0 (flat roof), 15, and 26.7.

CORRELATION OF THE RATIO OF NON-METHANE HYDROCARBON AND NITROGEN OXIDES CONCENTRATION IN THE ATMOSPHERE AND OUTDOOR ENVIRONMENT

The correlation of atmospheric pollution by VOC and NMHC/NOX ratio has been found. By usingNMHC/NOX ratio, the source of NMHC in the region can be presumed without effects from the diffusionand the dilution by the meteorological conditions. At general measurement station in A city OsakaPrefecture, the NMHC/NOX ratio shows high value in summer though NMHC and NOX concentrationshow high value in early winter. As opposed to city A, traffic measurement station C doesnt show thispattern. It suggests that the amount of the exhaust of NMHC increases along with the temperature.

MONITORING CEREBRAL BLOOD FLOW FOR OBJECTIVE EVALUATION OF RELATIONSHIP PRODUCTIVITY AND THERMAL ENVIRONMENT

It is difficult to evaluate the effect of indoor environmental quality on productivity by measuring only taskperformance. In this study, the monitoring of cerebral blood flow during task by Near InfraredSpectroscopy is introduced as one of the objective evaluation methods of workers human responsethat are factors affecting task performance.

INVESTIGATION OF BEHAVIOR PATTERN AND RISK-ASSESSMENT OF MAIN INDOOR AIR POLLUTANTS IN SAPPORO AND NAGOYA CITY PART 2: NATURAL RADIOACTIVE SUBSTANCE

Radon short-lived decay products generated from the earth is one of the serious indoor air pollutantsin Europe and US. We measured natural radioactive substance and main indoor air pollutants in thefacilities of Sapporo and Nagoya City. The main measured items were composed of 1) air temperature,2) air humidity, 3) CO2, 4) CO, 5) HCHO, 6) VOCs, 7) airborne fungi,8) airborne bacteria, 9) SPM and10) Rn and Rn-Dts. The subjected spaces were laboratories, lecture rooms, libraries, museums, publicunderground spaces, closed spaces without window and outdoors.

OPTIMUM ADDITIVE LEVEL OF ORGANOPHOSPHATE FLAME RETARDANTS IN MATERIALS

Flame retardants have been used in polymers to reduce the flammability of plastics, building materials,fabric and papers. In recent years, organophosphate flame retardants were used as substitutes forBrominated Flame Retardants. The consume amounts of organophosphate flame retardants in 2001was about 5 times than that of 2000 in Japan. Recently, several studies have shown the carcinogenicityand neurotoxicity of organophosphate flame retardants. Reducing the risk of fire is the main advantageof using organophosphate flame retardants.

STUDY ON OPTIMIZATION OF DESIGN AND OPERATION FOR GROUNDWATER HEAT PUMP SYSTEM BASED ON REAL-SCALE EXPERIMENT AND NUMERICAL SIMULATION

The groundwater heat pump (GWHP) system is an open-loop system that draws water from a well orsurface water, passes it through a heat exchanger and discharges the water into an injection well ornearby river. By utilizing the relatively stable temperature of groundwater, this system can achieve ahigher coefficient of performance and offers a more energy-saving solution than the conventionalair-source heat pump (ASHP) system. On the other hand, its performance significantly depends on thecharacteristics of the groundwater and the underground thermal properties.

CHEMI-LESS TOWN PROJECT TO PREVENT SICK BUILDING SYNDROME: FROM THE VIEW OF THE ENVIRONMENTAL PREVENTIVE MEDICINE USING SUSTAINABLE HEALTH TOWN BY DECREASING THE USE OF CHEMICALS

There is increasing number of people suffering from “Sick-building Syndrome” in Japan. Therefore, we started “Chemi-less Town Project”, building a model town in which buildings are constructed with fewer chemicals. In this paper, we introduce the backgrou

IMPACT OF THE TEMPERATURE AFFECT UPON THE RESIDENTIAL ENERGY CONSUMPTION FOR AIR-CONDITIONING

This paper presents a study of the impact of urban warming upon energy consumption forair-conditioning in the home, using a numerical simulation model. The results are as follows. 1) In citiesother than Sapporo and Sendai, about 50% of the total hours of occupancy were ventilation hours, andabout 20% to 40% were cooling hours. As a result, the total energy consumption for cooling wascomparatively large. 2) In these other cities, cooling hours increased in the summer as the outdoortemperature rose.

FIELD SURVEY AND STATISTICS ANALYSIS ON IAQ, BUILDING PERFORMANCE AND OCCUPANT’S HEALTH OF 60 HOUSES IN JAPAN

In order to determine the causes of SHS (Sick House Syndrome), a field survey on indoor air quality and occupants’ health conditions was investigated in 60 houses in Japan. As a result, when houses that more than one occupant are “SHS” count as “Sick Hous

Policies and Technical Guidelines for Urban Planning of High Density Cities – Air Ventilation Assessment (AVA) of Hong Kong

In 2003, Hong Kong was hit by Severe Acute Respiratory Syndrome (SARS) from which many peopledied. The Hong Kong Government subsequently set up a Governmental Team Clean Committee toinvestigate possible urban design policies. Team Clean charged the task to the Planning Department,HKSAR. It initiated a study titled: Feasibility Study for Establishment of Air Ventilation Assessment(AVA) System. In 2003, the research contract was entrusted to a team of researchers of Departmentof Architecture, CUHK. A number of focused studies were conducted.

Pages