An improved procedure for developing calibrated hourly simulation models

In order to improve upon previous calibration techniques, this paper presents new calibration methodsincluding a temperature bin analysis to improve hourly x-y scatter plots, a 24-hour weatherdaytype bin analysis to allow for the evaluation of hourly temperature and schedule dependent comparisons, and a 52-week bin analysis to facilitate the evaluation of long-term trends. In addition, architectural rendering is suggested as a means of verifying the building envelope dimensions and external shading placement.

An error analysis method applied to a building simulation software : an example of application and its results

Within the framework of an Anglo-French validation project funded by EDF and the BRE, a building model has been tested using an error analysis method. The first step enabled the identification of the different discrepancy sources. The second step pointed out the way the model should be improved to fit to reality. Presently, the major accuracy gains can be expected from improvements on heat exchange between air and heating system, glazing modelling and solar radiation distribution.

Air flow pattern and temperature field simulation in a large glazed space

Air velocity and air temperature are, in large glazed spaces, very heterogeneous and time dependant. Indoor and outdoor thermal conditions, localized solar radiation effects and ventilation systems are the conditions for mixed convection situations which produce, in large enclosures, significant velocity and temperature gradients. In this paper we describe the numerical techniques and processes that enable us to take these three types of conditions into account.

Advancing lighting and daylighting simulation: the transition from analysis to design aid tools

This paper explores three significant software development requirements for making the transitionfrom standalone lighting simulation/analysis tools to simulation-based design aid tools. These requirements include specialized lighting simulation engines, facilitated methods for creating detailed simulatable building descriptions, and automated techniques for providing lighting design guidance. Initial computer implementations meant to address each of these requirements are discussed to further elaborate these requirements and to illustrate work-progress toward fulfilling them.

A wind pressure distribution calculation program for multizone airflow models

Multizone airflow modelling is used for IAQ analysis as well as evaluation of cooling potential in buildings. A detailed evaluation of the wind pressure distribution on the envelope of a building is important for multizone: airflow modelling. There are a number of variables affecting the pressure distribution around a building due to natural wind. Wall-averaged values of Cp usually do not match the accuracy required. for multizone: airflow models.

A translator from NMF to spark

In this paper we review the basic concepts of the Neutral Model Format for component description, of the SPARK objet-based simulation environment, and present a translator from NMF to SPARK. The purpose of the above is to document the NMF claim that translation from NMF to any simulation environment is easy, and also get a feeling of the effort needed to obtain a workng translator. The translator presented handles most NMF constructs (equations, loops, sums, embedded controls) with the notable exception of events. Working examples of translator-generated code are then presented.

A statistical methodology for model validation in the allan: simulation environment

This paper deals with the model validation methodology used at the Gaz de France Research & Development Division. The primary emphasis is on the latest developments, concerning different statistical methods for model validation and diagnosis. The corresponding computer implementation is called DVM standing for "Diagnostic et Validation de Modles".

A simulation model applied to climatization plant performance analysis in presence of thermal storage

A comprehensive simulation model, based on the TRNSYS program, for the evaluation of thermalstorage system behaviour in building climatization is presented here. The algorithm is applied to the study of a typical office building in presence of an ice or water storage. Possible economic advantages are presented and analysed. The remarkable differences obtained with different plant options confirm the necessity of an accurate study and justify the use of comprehensive computer models.

A simulation approach to determine a visual comfort index including daylight for adequate building performance evaluation

Building performance evaluation requires accepted standards for comparison. Thermal comfort conditions are widely accepted. This is different for lighting issues: currently set standards are far from describing user comfort sensations. Since both natural and artificial lighting have significant impact on the total energy demand, future building performance evaluation will need to take this into account. Inclusion of daylight as an extremely variable light source makes it virtually impossible to perform subjective tests under reproducable test conditions.

A simplified coupled model for thermal behaviour and air flows simulation in urban spaces

The studies presented here aim at defining and setting out a calculation code allowing the prediction of outdoor ambient thermal quality. Designers of urban spaces are expecting more specialized information such as skilled rules which may be achieved by the presented code, at present in process of development. The physical system is identified as being representative of the urban network of an average town like Saint-Denis, Reunion Island (about 60 000 inhabitants). The calculation code, made up by assembling different models, describes the thermal behaviour of the physical system.