Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 18:57
Portugal introduced, for the first time, in the 2006 Building Regulations, a requirement on the airtightness of the ductwork in new HVAC installations. A test is required during commissioning. Data on compliance is however still quite scarce to conclude how effective this requirement is in practice.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 16:50
This paper presents some results from the Work Package 5 in the HealthVent project supported by the European Commission. One of the objectives of the project has been to review and critically evaluate the existing requirements on ventilation and IAQ defined in national building codes and European standards. The project’s focus has been set on ventilation rates, pollutants, noise, temperature and draft in dwellings, offices, schools and kindergartens. This paper presents a summary of the values given in European regulations and results of comparisons.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 16:12
The Proceedings of the 31st AIVC Conference " Low Energy and Sustainable Ventilation Technologies for Green Buildings", held in Seoul, Korea, 26-28 October 2010.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 16:03
Air leakage test was carried out according to ASTM E779-03, Standard Test Method for Determining Air Leakage Rate by Fan Pressurization to meet the requirements of the LEED-NC v2.2(EQp2). Air leakage tests for quality assurance can be performed once all work on the air barrier has been completed and all windows and doors have been installed in two high-rise residential buildings. Test units selection was carried out in accordance with the following guidance, California’s 2001 Energy Efficiency Standards.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 16:02
Recently, in order to reduce energy consumption in the building sector, many air-conditioning systems have been proposed and applied to real buildings. Of particular note, air-conditioning systems that treat sensible and latent loads separately have been assessed as efficient in hot and humid climates. In this study, a highly efficient desiccant system combined with a cogeneration system and a heat pump desiccant system has been developed.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 16:00
Cold storage is a way to deal with peak cooling loads. Cold storage integrated with building structures is independent of the approach used for building cooling – it can be used with passive cooling as well as mechanical cooling. High thermal storage capacity in a narrow temperature interval makes phase change materials (PCMs) a suitable medium for cold storage in built environments. A set of experiments was performed with the aim to investigate performance of PCM cold storage in building structures under various ventilation strategies.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 15:59
We developed a method for estimating effective flow areas not only in the external wall of a house but also in the internal walls between rooms using only one type of tracer gas. This method is based upon the following hypotheses: (1) the temperature and tracer-gas concentration in the room is homogenous, (2) the air in the room is in a windless state, (3) there is no error in the measurement of tracer-gas concentration. However, we know that in reality, these hypotheses are not entirely true.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 15:57
This paper is mainly present the filtering technology for air purification in the process of ventilation and air conditioning. By the means of reviewing the related research we have made in this area, several effective programs for PM10 filtration are introduced from the view of experimental testing and practical applications. However, the selection and screening of fiber filter material has yet to be standardized, and the development of new multi-functional and energy efficient fiber filter material is pressingly required.
Submitted by Maria.Kapsalaki on Thu, 10/31/2013 - 15:55
The aim of this study is to find out a role of the computer simulation on sustainable design projects and development of façade elements with results of daylighting simulation and energy performance. 3D components of façade modeling get to realized in Rhino 3d with some help of Paracloud encoding. With simulation program of Ecotect and eQuest, thus, the result will show influencing factors of each generative components on the radiation & dayligthing factors.