Presents a model for computing the infiltration and air flow between rooms of a multi-room building in terms of basic principles of fluid mechanics. This model has been incorporated into a comprehensive loads-predicting computer program. Air flo
Discusses different ways of defining and comparing ventilation efficiency. It can be defined in absolute values ie the ability of the system to decrease the concentration of impurities in proportion to the maximum concentration. A time consta
Discusses the ASHRAE Standard 62-1981 "Ventilation for Acceptable Indoor AIr Quality", and extensive field measurements of ventilation. Presents apredictive model for indoor air contaminant concentrations in residences andits verification, along with the effects of several variables. Additional research on the indoor emanation rates of contaminants which are health hazards would enable the prediction of indoor contaminant levels with various control options.
Describes a program which enables a hand-held computer to perform the energy audit calculations used in Building Practice Note No.20 "Estimating energy savings from reinsulating houses". The computer prompts the user for information, and provides a fast and versatile way of performing energy audit calculations.
Summarizes the information obtained concerning new residential construction in the US and points out important differences between US and Swedish technology and construction methods for energy efficient housing. Selected building components for US housing are described and compared with corresponding Swedish techniques. Most important differences are -1. Differences in ventilation strategies - almost all new Swedish houses have continuous mechanical ventilaton. 2. The airtightness of building envelopes. 3. Wall constructions and standard insulation practices.
Natural ventilation can be used to reduce cooling loads and increase human comforts in buildings in hot humid climates. Airflow rates are determined by the wind pressure on the faces of the building and the amount of open area. Describes wind pressure coefficient measurements made on 2 buildings at theKaneohe Marine Corps Air Station on the island of Oahu, Hawaii during summer 1982. These full scale measurements will be compared to reduced-scale measurements made of the boundary-layer wind tunnel at the Naval Civil Engineering Laboratory.
Fan pressurization tests on 2 unoccupied houses have been conducted once every 2 weeks for a period of a year to determine the seasonal variation in air tightness. House no.1 was built with more insulation than is required by the local building
Examines the sensitivity of the predicted air infiltration rate to measured building air tightness data and the wind exposure index determined from site inspection. Presents results of air tightness tests in New Zealand houses, which indicate the range of leakage resistance for components, for solid materials (such as wall and ceiling lining materials) and for cracks separating major components such as floors and walls.
A major pathway for loss of conditioned air in east Tennessee homes with externally located HVAC systems is leakage in the ductwork. The effect on infiltration rates, as measured by Freon-12 tracer gas dilution, becomes marked if the central duct fan is operating. Duct fan on and duct fan off measurements of the rate of air exchange gave mean values of 0.41 and 0.78 ach respectively in a total of 31 homes.
Describes a calibration technique to relate the air flow rate through a blower door to the fan speed and pressure difference across the door. To obtain an accurate and well-documented calibration of pressurization devices, a facility was designed and constructed at the US National Bureau of Standards. This accurately determines the flow rate through the fan as a function of fan speed, air density and pressure difference across the fan.