The relation between air infiltration rate and indoor concentrations of radon gas, radon daughters, and formaldehyde has been investigated for both summer and winter conditions in a number of Toronto houses with low rates of natural ventilation.
Possible health effects and changes in sensation of comfort among tenants after replacement of single glass windows in leaky frames with double glass windows in airtight frames have been studied. The study design was observational, and included a study group and a corresponding control group. The results indicate essential improvements of the indoor climate and of the health status of the tenants after replacement of the windows (i.e.
Reduction of fresh air ventilation is becoming the major means of energy conservation in office buildings. Simultaneously, health and comfort problems experienced by occupants are often suspected to be a direct result of reduced fresh air ventilation. However, there is little data available on health and comfort problems experienced by occupants of buildings operated under normal ventilation rates.
The air tightness of 15 detached houses was measured firstly immediately after erection and secondly after a period of 1.5 to 4.5 years. All the houses were timber framed ones, equipped with mechanical ventilation systems. Only two houses out of the 15 tested showed clear changes in air tightness. Thus the air tightness behaviour of the houses seems to be fairly constant.
Since 1970 measurements of air change rate have been carried out in about one thousand buildings by the Swedish Institute for Building Research (SIB). In this paper we present results from these measurements. The studied buildings are of various design and have ventilation systems of different types, natural as well as mechanical. The buildings include single family houses, row houses, and multi family residential buildings, erected between 1900 and 1982. The measurements have then been carried out using tracer gas (decay) techniques to determine the rate of air exchange.
In 1981 Norwegian building regulations introduced quantitative requirements to air leakages in different types of buildings. The requirements were formed as maximum allowed air changes per hour at 50 Pa pressure difference according to the pressurization method. To evaluate the consequences of these new requirementsimposed to Norwegian building industry a model proposed by the Nordic Committee for Building Regulations (NKB) was used. The average air leakages of residential buildings , built before the new requirements,are known through a research project performed i n 1979.
Air infiltration typically accounts for a third of the energy loss in a heated building. The driving forces for natural air infiltration are wind and temperature differences. For a given combination of weather conditions the amount of air infiltration is determined by the character of the building envelope, mainly its airtightness. A useful technique in characterizing this housing quality is to measure air leakage. An air leakage standard for new construction has been in effect in Sweden since 1975.
A microprocessor system is being developed for occupancy related ventilation control of mechanical ventilation in Brunel University Library. The objective is to reduce space heating costs by decreasing the input of (cold) fresh air to the building below existing (heating season) levels, when the number of occupants in the building is sufficiently small to allow this. The occupancy levels can be measured in terms of CO2 level in the exhaust duct. The microprocessor control system is operational when linked to a CO2 monitor.
This paper compares the conventional exhaust system with a supply-exhaust system with regard to the possible degree of control of the air exchange in the individual rooms. Ventilation efficiency and air exchange efficiency are defined and some examples show the local concentration, mean ventilation efficiency and mean air exchange efficiency for some simple ventilation schemes. Exhaust systems require a very tight building with small make up air openings. The ability of the different systems to avoid leakage out from the building of indoor air is also compared.
Ventilation standards in buildings are receiving increased attention because of energy conservation and indoor air quality. An important example of this is the current ASHRAE Standard 62-1981, "Ventilation for Acceptable Indoor Air Quality." This standard contains two distinct procedures that can be used to set ventilation rates. The first is a prescriptive specification that mandates ventilation rates for particular building types. The second is a performance specification that uses target concentrations of indoor contaminants as the basis for deciding the adequacy of ventilation rates.