A New Development for Total Heat Recovery Wheels

Total energy exchangers with a rotating heat storing matrix have been applied to air conditioning systems for more than 25 years with very good results for saving both heating and cooling energy. The efficiency of the hygroscopic coating of the rotors is very important to recover the latent energy, but there is the risk of cross contamination. To prevent odour transfer, the mechanism of the sorption and desorption process has to be investigated in detail.

Energy Impact of Ventilation and Dynamic Insulation.

Dynamic insulation stands for an insulation through which an air flow flows. The air flow is usually the normal ventilation flow. The air can flow in the same or in the opposite direction of the normal heat flow. The dynamic insulation can be arranged as single where only inlet or exhaust air passes the insulation, or as combined where inlet and exhaust air pass one half of the insulation each. Dynamic insulation using exhaust air might result in condensation problems in cold climates.

Natural Ventilation via Courtyards: Theory & Measurements.

Existing regulations concerning the design and construction of residential buildings which are naturally ventilated via courtyards and lightwells have origins in daylighting rather than in aerodynamics. The design of narrow, high-sided courtyards which achieve healthy . conditions for occupants, has long been a problem and a subject of various guidance and research, although many doubts and gaps in knowledge still remained. The work described below resolves these problems, and the coherent theory developed may lead to clearer guidance on the design of courtyards for natural ventilation.

The Influence of Purpose-Provided Openings on Natural Ventilation of Buildings Equipped with Gas Fired Appliances.

The growing diffision of small power, gas-fired individual units for space heating and service hot water production, as well as concern about operational safety issues, has promoted greater attention to the understanding of ventilation mechanisms in the dwellings equipped with such units. Within a joint research project between Politecnico di Torino and Italgas, an experimental campaign has been conducted in order to investigate the influence of purpose-provided ventilation openings (sized according to the national UNI-CIG 7129-72 standard) on air changes and IAQ.

The PLEIADE Dwelling: an IEA Task XIII Low Energy Dwelling with Emphasis on IAQ and Thermal Comfort.

The major objective of the IEA task XIII project is to design and construct low energy dwellings which should be technically and economically realistic in the period 2000-2010. The design criteria for the Belgian dwelling are the following: - low energy demand for heating purposes; - good thermal comfort conditions, as well in winter as in summer with attention to the problem of overheating; - very good airtightness (n50 <= 1 h^-1); - good indoor air quality conditions; - attractive design for majority of potential clients; - only use of realistic technical solutions.

The Influence of the Humidity on Thermal Comfort, Heat Load Calculation and Cooling Capacity.

This paper shows the extensive influence of humidity on comfort, cooling load and refrigeration capacity. Modern computer programs allow an effective consideration of humidity in systems.

Moisture Admittance Model: Measurements in a Furnished Dwelling.

The BRE method of predicting water vapour conditions in houses is based on two generalised moisture admittance parameters a and p. Previous laboratory experiments suggested that it is possible to determine these coefficients for an unfurnished room with wooden panels, using measurement periods of six hours under dynamic equilibrium conditions. The present study explores the possibility of using such conditions to determine a and P in-situ for the living-room and bedroom of a furnished flat of conventional construction.

Numerical Assessment of Room Air Distribution Strategies.

The air distribution in a room is investigated using computational fluid dynamics. Four common methods of supplying air to a room are compared. The effect of air change rate on the ventilation effectiveness for contamination is small, however the effect of room heating or cooling load can be very significant. It was found that air turbulence has a major influence on the air movement, air velocity and dispersion of contaminants in the room.
 

Benefits and Limits of Free Cooling in Non-Residential Buildings.

In urban non-residential buildings air-conditioning systems are generally required to achieve acceptable air quality. To reduce the energy demand of HVAC-plants free cooling is proposed. The present study deals with free cooling by outdoor air (untreated or additionally cooled by evaporation) during the night. Therefore a sufficient building mass (about 600 to 800 kg/m²) is necessary which stores the heat produced in daytime and which is cooled down at night. In most conventional non-residential buildings, however, the building mass is at about 400 to 600 kg/m².

Stack Effect Ventilation of an Infant's School.

This paper presents the results of monitoring the ventilation in Netley Infants School in Hampshire. The study was carried out on behalf of the Department of Trade and Industry as part of the Energy Performance Assessment Project, as managed by the Energy Technology Support Unit. The school was designed so that during the summer the solar heating of a south facing conservatory would enhance the stack effect and induce ventilation in the adjacent classrooms. It was expected that ventilation rates would be adequate to maintain comfort conditions and air quality.