Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

The experiments are carried out in a climate chamber located at the Department of Civil Engineering Aalborg University. The objective of the experiments is to evaluate the performance of the system combining diffuse ceiling ventilation and thermally activated building construction (TABS) in terms of thermal comfort and energy performance. 20 cases with different boundary conditions are conducted varying on climate condition heat load. TABS water temperature and flow rate with or without diffuse ceiling.

Integrated Solution in an Office Room with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

This work presents an energy assessment of the natural ventilation performance within buildings located on both hot-temperate and mild-temperate conditions such as the existing along the central region of Mexico. With the assistance of a coupled thermalairflow simulation program, simulations are run without and with natural ventilation, respectively. Thereby, the consumption of air-conditioning presented in this region is validated with data from literature when natural ventilation is not applied.

Experimental study of diffuse ceiling ventilation coupled with a thermally activated building construction in an office room

This paper presents and analyses the performance of an integrated system with diffuse ceiling ventilation and a thermally activated building construction. A full-scale experiment is carried out in a hot box with an office setup. The performance of the integrated system is evaluated under different boundary conditions, considering different weather conditions, internal heat loads, TABS activation modes and with/without diffuse ceiling. The measurement results indicate that the diffuse ceiling plays a beneficial role improving thermal comfort in the occupied zone.

A novel system solution for cooling and ventilation in office buildings: A review of applied technologies and a case study

As a response to new energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need both in summer and in winter. In order to effectively save energy, new interests in cooling concepts using passive cooling technologies and renewable energy sources have risen. Based on a literature review of natural ventilation, building thermal mass activation and diffuse ceiling ventilation, this paper proposes a new system solution combining these three technologies for cooling and ventilation in office buildings.

Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS

This paper investigates the dynamic cooling performance of a novel system combining natural ventilation with diffuse ceiling inlet and thermally activated building systems (TABS). This system is tested in the lab under three climatic conditions representing typical seasons in Denmark, including a typical winter day, a typical day in the transitional season and a typical summer day. The corresponding dynamic control strategies have been designed for these three cases in the measurements.

Experimental investigation of cooling performance of a novel HVAC system combining natural ventilation with diffuse ceiling inlet and TABS

A novel HVAC system combining natural ventilation with diffuse ceiling inlet and thermally activated building systems (TABS) has the ability to fulfill the requirements of cooling and ventilation in future Danish office buildings. In order to study the cooling performance of this system, a test chamber is constructed in a way to represent the characteristics of an office room. Twenty cases are tested under steady-state conditions, including ten cases without ceiling panel and ten cases with ceiling panel.

Overheating risk barriers to energy renovations of single family houses: Multicriteria analysis and assessment

Many post-occupancy comfort studies of energy renovated residential buildings have documented elevated temperatures above comfort levels, not only during the summer period but also during the shoulder months. The main focus in renovation projects is on heat savings while the risk of overheating is not considered.

Control Strategies for Ventilative Cooling of Overheated Houses

Buildings constructed before 1979 in Denmark are responsible for 75% of the total energy consumption of the sector. However, many post-occupancy comfort studies of energy renovated dwellings have documented elevated temperatures not only during the summer period but also during the transition months. Ventilative cooling can be an energy-efficient solution to avoid overheating in energy renovated residences.

Overheating assessment of energy renovations

In many post-occupancy studies of renovated houses elevated temperatures have been documented. This article presents in which situations overheating need to be addressed and which renovation measures are causing this need. The analysis contains representative houses from central and north Europe. Both dynamic and static overheating assessment criteria are used.

Dynamic Measurements of a Novel System: Combining Natural Ventilation with Diffuse Ceiling Inlet and Thermally Activated Building Constructions

In the PSO project 345-061, a novel system solution combining natural ventilation with diffuse ceiling inlet and thermally activated building systems (TABS) has been proposed for cooling and ventilation in Danish office buildings. Due to the application of diffuse ceiling inlet, cold outdoor air can be supplied into the room without any risk of draught even in the extreme winter. This means that natural ventilation is available even in winter and it is beneficial to reduce the energy consumption for buildings with cooling demand in cold seasons.