Experimental studies of the air quality evaluation.

Three buildings are investigated to study the indoor air quality and the impact of the outdoorair pollution. These buildings, a swimming pool, a school and a nursery are located in anurban area. So, during experimental studies, typical outdoor and indoor pollutants such ascarbon monoxyde, nitrogen dioxyde, carbon dioxyde, and total volatile organic compoundsare monitored. Also, the relative humidity and the temperature are carried out. The analysisallows us to reveal several points.

The control of air quality in a Chinese kitchen.

Chinese food is delicious. There are many kinds of cuisine. But the stir-fry, fry and deep-fry produce a large amount of steam and smoke which cause indoor air pollution seriously. So it must be controlled. The paper gets some flow distribution regularity of steam and smoke current in Chinese cooking by testing in laboratory and advances a new method to prevent the diffusion of smoking current-kitchen hood with forced air screen. By comparing with other removers, the equipment can save heat (cold) load and improve indoor air condition greatly.

Must cold air downdraughts be compensated when using highly insulating windows?

Rooms with high windows are likely to have comfort problems caused by cold airdowndraught, which are usually solved by placing heating appliances underneath thewindows. In the city of Zug, Switzerland, a highly insulated educational building with aconcrete core system for heating and cooling is planned. The purpose of our investigation wasto find out whether any measures are necessary in this building to compensate the effects ofdowndraught in the occupied zone. Special attention has been paid to the effect of passivemeasures like air flow obstacles or openings in the window sill.

Indoor air quality and performance contracting in schools in the US.

The U.S. Environmental Protection Agency (EPA) in partnership with the NationalAssociation of Energy Service Companies (NAESCO) is demonstrating an approach whichintegrates indoor air quality (IAQ) improvements into energy efficiency upgrades provided toschools using performance contracts. Capital costs of energy-related improvements arefinanced, then repaid from utility and maintenance savings realized as a result of newequipment, systems, and controls. In five public schools in various climate zones across theU.

Low temperature heating systems: impact on IAQ, thermal comfort and energy consumption.

The Netherlands Agency for Energy and the Environment(NOVEM) is conducting a program for the implementation of Low Temperature Heating (LTH) systems in buildings. The primary goal is to enable the use of Low Talued Energy as a heating source. Major savings in enery consumption can be realised by fully utilising the potential of Low Valued Enery. Besides the argument of savings in energy supply, there are additiond benefits in the fields of. Indoor Air Quality (particles, mites, lower air temperature, annoyance and dust);.

The influence of nocturnal ventilation reduction on indoor air quality.

The energy saving practice of stopping ventilation systems at night may reduce the daytimeair quality. Sorption phenomena where pollutants absorbed at night are reemitted during theday and the general slower removal of pollutants at the reduced average ventilation rates willcontribute to the deterioration of air quality at intermittent running systems. The purpose ofthe study was to investigate the impact on construction product emission during the day fromreduced ventilation rates at night. Experiments were performed in three small-scale chambersof Climpaq type with dilution systems.

Wind driven and thermal air flow patterns at courtyards.

Air flow patterns and temperature distribution within courtyard have been studied. Wind and thermally driven flow have been thoroughly analysed as a function of the depth to width ratio (Aspect ratio) as main parameter. CFD results show a quite similar behaviour regarding to velocity profiles for all the cases, though temperature profiles are highly affected by dimensions of the courtyard. The whole study can be extrapolated to urban canyons, where air flow patterns are quite similar as a result of having the same geometry.

Solar access, passive cooling and microclimate in the city: the Polis project.

This paper describes a European project to produce comprehensive design guidance on urban layout to ensure good access to solar gain, daylighting and passive cooling. The project involves:

Ventilation efficiency in dwelling cells: contribution to the validation of a zonal model.

Since reduction of ventilation rates in dwellings for economical reasons, it has been necessary to study whether this reduction had not been done to the detriment of indoor air quality. Several means of investigating were developed: experimental tests are indispensable but usually expensive that is why numerous research centres choose to model the thermoconvective fields in rooms.

Measurement of air flow rates and ventilation efficiency in air handling units.

The use of tracer gas is of great help in measuring airflow rates and detecting shortcuts in air handling units, and is essential for ventilation efficiency measurement. However, the planning of experiments, that is choosing tracer gas injection locations and air sampling locations, is not straightforward. Moreover, the mathematics used for interpretation are quite complex, and require elaborate calculations. Therefore, a measurement protocol and the corresponding interpretation algorithms are being developed and implemented in a user-friendly computer program.