Duct cleaning: Do homes need it ?

This paper gives a description of the cleaning of metal ducts in small buildings, located in heating climates in the northern US states, with different cleaning techniques, their cost, and advices from different trade associations.

Implications of ASHRAE's guidance on ventilation for smoking-permitted areas

This article presents the difficulty for ASHRAE to take into account the high levels of ventilation requiries and to combine them with the demand for "guidance" encouraged by the tobacco industry and its allies.

Three approaches to replacement air delivery

This article focuses on the replacement air component for atrium smoke exhaust, including comparisons of three design approaches. The concepts are illustrated by case studies.

Sizing VAV boxes

This article sums up a detailed analysis of variable air volume (VAV) box control. Sizing criteria are provided in order to minimize the life-cycle cost in typical application.

Best practices for selecting diffusers

As the office environment is always changing new ways of looking at diffuser selection is mandatory.Changes in the office air delivery system may be due to new building codes/regulations, or to changing interior loads.New technologies allow innovative manners to treat heating and cooling needs. Some strategies may be used in retrofitting.

HVAC system performance in large office buildings: ventilation, source control and filtration support air quality

In this paper the author develops the key factors that influence the performance of ventilation systems mainly in large office buildings. Information for the efficient operation of these systems is provided.

Approach for the improvement of energy performance of a stock of buildings

This paper is a sum-up of the work performed by CSTB, ADEME and the Ministry of Equipement in France to improve the energy performance of the huge ministry stock of buildings (10 000 buildings of different size and uses). The objective of the project was to evaluate the performance of the buildings and to improve it in close work with the end-users.

Broadband fan noise prediction using single-airfoil theory - Part 2: experimental validation.

The analytical model described in the first part of the paper is partially validated here by comparing the theoretical results to experimental data collected in a series of model test experiments in an open-jet anechoic wind tunnel. The emphasis is on the validation of the trailing-edge noise model. A comparison is made with existing numerical computations in the literature. The transfer function is found to be roughly invariant with respect to flow conditions encountered on an isolated airfoil. Furthermore, a first application of the model to a cooling fan is presented.

Broadband fan noise prediction using single-airfoil theory - Part 1: Theoretical background

This paper, the first of 2 parts, is dedicated to the analytical modeling of the broadband noise radiated by subsonic fans, such as encountered in HVAC or engine cooling applications. A fan noise prediction scheme is proposed on the basis of single-airfoil linearised unsteady aerodynamics theories. Spanwise distributed sources only are investigated, corresponding to three basic mechanisms, namely the noise from impingement of upstream turbulence, the trailing edge noise associated with turbulent boundary layer scattering, and vortex shedding noise.

Design of a low noise axial fan

This paper is a description of the design process of a new generation low noise axial fan. The emphasis is on the practical use of acoustic knowledge issued from published work and engineer know-how. The use of date issued from numerical simulation is also presented.