Improved model to simulate air flow rate through an opened window

The author describes how to improve the usual formula to calculate air flow rate through an opened hopper window.Improvements consist in better taking into account the geometry of such windows when estimating their opened area and also in adapting to this type of windows the model used to take into account the influence of wind and of thermal draught.Improved model gives a good comparison with on site measured data from the literature.

Impact of airflow profile on indoor air quality - a tropical study -

The simulation of airflow pattern in an office building in Singapore is based on the environmental conditions and the corresponding ventilation parmeters measured on a typical day. The findings of that study are reported in this paper.

On ventilation of a heated room through a single doorway

First laboratory experiments are presented, the aim is to examine the transient filling of a room of buoyant fluid when a doorway connects the room to a large reservoir of dense fluid. A model of the transient exchange flow is then presented, it is in accordance with the experimental results.
A layer of air, warmer than the exterior must be maintained above a cold layer near the floor to prevent the heat supplied to the room to be lost through the doorway.

A study on the identification and quantification of sources of VOC's in 5 air-conditioned Singapore office buildings

For that study a mass balanced model is applied to determine area-specific emissions rates in office buildings. Sources of VOCs were identified, put into 3 broad categories and quantified : building materials (23.7 %), ventilation systems (39.0 %) and occupants and their activities (37.3 %) .

Effects of outdoor air conditions on hybrid air conditioning based on task/ambient strategy with natural and mechanical ventilation in office buildings

The aim of this study is to clarify the effects of indoor environmental characteristics of hybrid - natural and mechanical - air conditioning systems in office buildings during intermediate seasons. The other objective was to obtain design data.

Effect of internal partitioning on indoor air quality of rooms with mixing ventilation - basic study -

This paper sums up the results of a study on the internal partitioning with its effects on the room air quality along with the ventilation performance. Physical tests and numerical modeling for a CFD simulation were used to evaluate different test conditions that employed mixing ventilation from the ceiling.

Comparison of indoor aerosol particle concentration and deposition in different ventilated rooms by numerical method

Indoor aerosol particles, their concentration and deposition in displacement, their movements in two ventilated rooms are compared numerically. For the simulation of particle tracks, the discrete trajectory model is adopted whereas the Eularian method is used for solving the continuous fluid flow.

Performance of ventilation system in a non-standard operating room

In Hong Kong, design and construction of new operating rooms and upgrading of older ones have been based on the UK Health Building Notes. In a case study, field measurements showed that the airflow and some design features did not tally with the specifed requirements.
As the risk of contamination in an operating room can be minimized through appropriate filtration and air distribution scheme, a CFD analysis was carried out with the simulation of the temperature distribution, airflow pattern and the contaminant dispersion.

The outdoor air ventilation rate in high-rise residences employing room air conditioners

This paper reports mainly on field studies were indoor overnight CO2 levels are monitored along with outdoor ventilation rates in bedrooms where room air conditioners are employed.The results of laboratory experiments using two typical RACs (room air conditioners) are also reported and discussed.

New indoor environment chambers and field experiment offices for research on human comfort, health and productivity at moderate energy expenditure

The international center for indoor environment and energy, at the Technical University of Denmark has at its disposal 3 old and 9 new spaces for studying indoor environments and their incidence on human comfort, health, productivity at moderate energy demands. This paper describes those climate chambers, new laboratory and offices used for field experiments.