The author describes how to improve the usual formula to calculate air flow rate through an opened hopper window.Improvements consist in better taking into account the geometry of such windows when estimating their opened area and also in adapting to this type of windows the model used to take into account the influence of wind and of thermal draught.Improved model gives a good comparison with on site measured data from the literature.
The simulation of airflow pattern in an office building in Singapore is based on the environmental conditions and the corresponding ventilation parmeters measured on a typical day. The findings of that study are reported in this paper.
First laboratory experiments are presented, the aim is to examine the transient filling of a room of buoyant fluid when a doorway connects the room to a large reservoir of dense fluid. A model of the transient exchange flow is then presented, it is in accordance with the experimental results.
A layer of air, warmer than the exterior must be maintained above a cold layer near the floor to prevent the heat supplied to the room to be lost through the doorway.
For that study a mass balanced model is applied to determine area-specific emissions rates in office buildings. Sources of VOCs were identified, put into 3 broad categories and quantified : building materials (23.7 %), ventilation systems (39.0 %) and occupants and their activities (37.3 %) .
The aim of this study is to clarify the effects of indoor environmental characteristics of hybrid - natural and mechanical - air conditioning systems in office buildings during intermediate seasons. The other objective was to obtain design data.
This paper sums up the results of a study on the internal partitioning with its effects on the room air quality along with the ventilation performance. Physical tests and numerical modeling for a CFD simulation were used to evaluate different test conditions that employed mixing ventilation from the ceiling.
Indoor aerosol particles, their concentration and deposition in displacement, their movements in two ventilated rooms are compared numerically. For the simulation of particle tracks, the discrete trajectory model is adopted whereas the Eularian method is used for solving the continuous fluid flow.
In Hong Kong, design and construction of new operating rooms and upgrading of older ones have been based on the UK Health Building Notes. In a case study, field measurements showed that the airflow and some design features did not tally with the specifed requirements.
As the risk of contamination in an operating room can be minimized through appropriate filtration and air distribution scheme, a CFD analysis was carried out with the simulation of the temperature distribution, airflow pattern and the contaminant dispersion.
This paper reports mainly on field studies were indoor overnight CO2 levels are monitored along with outdoor ventilation rates in bedrooms where room air conditioners are employed.The results of laboratory experiments using two typical RACs (room air conditioners) are also reported and discussed.
The international center for indoor environment and energy, at the Technical University of Denmark has at its disposal 3 old and 9 new spaces for studying indoor environments and their incidence on human comfort, health, productivity at moderate energy demands. This paper describes those climate chambers, new laboratory and offices used for field experiments.