Submitted by Maria.Kapsalaki on Wed, 06/18/2014 - 08:37
The moving human (MH) influences the airflow and contaminant distribution, this paper use the commerce software FLUENT6.2 to simulate the influences of the MH to the airflow and TVOCs distribution in both mixing ventilation and placement ventilation. In a three-dimension ventilation room, a pollutant source (TVOCs) was located on the floor and a flesh in a certain zone moving was assumed, and the unsteady, k-ξ turbulent model be used, According to the simulation results, we studied the influence of MH in the indoor air quality in both mixing ventilation and displacement ventilation.
Submitted by Maria.Kapsalaki on Wed, 06/18/2014 - 08:35
A data set of myriad and time-varying inhabitant-behavior schedules with a 15-minute time resolution, generated by the authors in a previous study, is validated through a comparison analysis. We show three comparisons. The first and second compare the estimated demand with a time series of actual utility demand. The comparisons indicate that the generated data and its algorithm, described by the authors, have an appropriate robustness.
Submitted by Maria.Kapsalaki on Wed, 06/18/2014 - 08:34
Building indoor environment quality (IEQ) has received growing attentions lately because of the extended time people spend indoors and the increasing reports of health problems related to poor indoor environments. Recent alarms to potential terrorist attacks with airborne chemical and biological agents (CBA) have further highlighted the research needs on building vulnerability and protection.
Submitted by Maria.Kapsalaki on Wed, 06/18/2014 - 08:32
This paper discusses the energy saving principle of frequency conversion chilled water system. Analyzes the energy saving failure reason in actual engineering from the pipe lines and the pump two aspects and gets out the reason is adopting the constant pressure difference control method. Through a simplified chilled water system, compares the pump energy saving efficiencies under constant and variable pressure difference control methods. Get out that the frequency conversion system can reach the maximum energy saving efficiency under variable pressure difference control method.
Submitted by Maria.Kapsalaki on Wed, 06/18/2014 - 08:30
Based on the generic dynamic building energy simulation environment, EnergyPlus, the simulation model of energy recovery ventilator (ERV) is built in this paper. With different indoor temperature setpoints, the energy performance of ERV along with the availability of ERV is investigated both for Beijing and Shanghai weathers in China in terms of the ratio of heat recovery to energy supply by HVAC devices and ERV. Simulation results show that the seasonal average of the ratio is linear with indoor temperature set-points.
Submitted by Maria.Kapsalaki on Tue, 06/17/2014 - 17:17
The research technical approach of this paper is based of the application of expert system for monitoring and fault detection in heating and air-conditioning systems. In the paper, introduces some diagnosis methods of the performance fault of heating and air conditioning, analyzes the principle.
Submitted by Maria.Kapsalaki on Tue, 06/17/2014 - 17:14
Using DeST Program, Simulation of Space Heating/cooling Load of two buildings has been conducted for Geo-Space Heating System using Gradient Utilization Techno- logy in university campus. Simulations were conducted in accordance with the different conditions: Temperatures & RH of Rooms, different sources of Weather Data, intensity of persons, Timetable of operation & Equipment, building constructions. Also measurement has been conducted using the measurement system. Then the comparisons between simulation & measurement were made.
Submitted by Maria.Kapsalaki on Tue, 06/17/2014 - 17:11
In order to solve the unbalance problem and increase the system efficiency of central heating, a new-style adjusting model in the building internal system —onoff valve adjusting system which is composed of by the on-off valve 、controller、 indoor temperature sensor is put forward.
Submitted by Maria.Kapsalaki on Tue, 06/17/2014 - 17:10
This paper discuss about characteristics and energy performance of personal air-conditioning system for a general multi-bed patient’s room. Two types of personal air-conditioning systems are evaluated by the laboratory experiment. Energy performance of a peri-counter FCU (a conventional) air-conditioning system is simulated by CFD to compare with that of personal systems. Compared with the conventional system, personal air-conditioning system has an advantage from the viewpoint of amenity improvement, but may consume more energy for cooling in the system.
Submitted by Maria.Kapsalaki on Tue, 06/17/2014 - 17:08
A methodology for optimizing the operation of heating/cooling plants with multi-heat source equipments is proposed. The methodology decides the optimal combination of the running of multiple heat source equipments to minimize the energy consumption of a heating/cooling plant. The optimal running combination is decided automatically using MATLAB® Stateflow® tool corresponding to cooling and heating loads. The energy consumption at different running combination is simulated using MATLAB® Simulink® tool. A case study is introduced to demonstrate the methodology.