In this study, we developed a numerical thermal manikin (NTM) with inner-body thermoregulation functions to investigate the local and overall thermal comfort in non-uniform thermal environments. The effect of interaction between human body and his/her environment was modeled by transferring air condition data from computational fluid dynamics (CFD) simulation into a thermoregulation model, feeding back the body surface temperatures from the inner-body model as boundary conditions to CFD, and then iterating until convergence.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:41
The advent of environmentally driven building regulations, rising energy costs, and heightened client awareness of energy-related issues has increased the demand for the assessment of building integrated low-carbon (LZC) energy supply systems. However, it is seldom the case that any one software tool fulfils the needs for an appraisal of these types of systems. Therefore, there is a clear need for an effective methodology for the use of a range of software tools in LZC technology analysis.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:39
This paper focuses on the environmental impacts assessment module recently implemented in an energy balance tool. It describes the data and the methodology used to evaluate these impacts. It is based on a life cycle approach and includes not only the energy consumption during the operation phase, but also the impacts of the contruction materials, from manufacturing to waste disposal. This tool has been used within the framework of a national projet to perform a life cycle assessment of 20 different buildings located in Switzerland. One of these case studies is presented in this paper.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:37
This paper presents the results of implementing 14 high-performance measures in a prototypical office building in a hot and humid climate using the DOE-2 simulation program. The objectives of this research were to discover high-performance measures applicable to office buildings in hot and humid climates and to develop a high-performance (maximum energy-efficient) building model that only uses technologies readily available in the contemporary market.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:35
Guidelines for isolation rooms in hospitals require keeping these rooms at negative pressure differential, but the guidelines do not impose a particular ventilation strategy how to achieve this. In principle, one could use variable ventilation regimes responding to interventions that cause a potential contamination risk such as the opening of doors. The variable ventilation regime would temporarily increase the volume offset and hence induce a higher negative pressure differential, whereas during other times the negative pressure differential would be kept at an acceptable minimum.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:26
This paper proposes an approach to the creation of design tools that address the real information needs of designers in the early stages of design of non-residential buildings. Traditional simplified design tools are typically too limited to be of much use, even in conceptual design.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:25
Despite the software developments intended to facilitate the use of energy simulation programs by architects in the early design stage, a very limited guidance is available, leading to a limited uptake. This paper investigates ways to better inform architects about energy simulation, firstly by enabling them to identify and translate the design inquiries into simulation tasks for deriving productive decision support and secondly by familiarizing them with the concepts and processes involved in energy simulation.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:23
This paper describes the modelling and analysis of a 5 MW chilled water plant used for the cooling of a recently constructed data centre in the UK. The model was developed using the TRNSYS software with the aim of studying the impact of perturbations such as chiller failure on the water and air temperatures in the system. The model includes the chillers, hydraulic network (piping, valves and pumps) and individual water-to-air heat exchange units.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:22
This paper presents the development of a novel school outline design, which can be applied in the different climate zones of Turkiye, underpinned by building performance simulation. The work builds on an earlier study, presented at the Building Simulation 2007 conference, which analysed the sensitivity of an existing scheme that had indeed been applied in all different climate zones, with different degrees of success. This follow-on project goes one step further and attempts to develop a new, more thermally robust school outline design.
Submitted by Maria.Kapsalaki on Mon, 06/23/2014 - 13:20
In the beginning of 2008 the new Dutch standard NEN 5060:2008 (NEN,2008) was published (status is still ‘preliminary’). The standard contains four new weather data files for various applications. The files are intended as replacement for the commonly used defacto standard “De Bilt 1964/1965”, which is used as a reference year for building performance simulation in the Netherlands. The Royal Dutch Metrological Institute (KNMI) has defined four possible future scenarios for the expected climate change.