Air change measurements in non-air conditioned rooms and the influence of building and climate parameters.Report 1. Luftwechselmessungen in nichtklimatisierten Raumen unter dem Einfluss von Konstruktions-und Klimaparametern. Bericht 1.

Presents the first of two sections of report 34020, detailing measurements carried out over the winter period of 1975/76 in Swiss dwellings with mainly hot water heating and some extract ventilation in kitchens and bathrooms. The aim of the research was to obtain a general picture of air change conditions in typical Swiss dwellings and to determine the effect of influencing parameters. The overall aim was to take a step towards the establishment of more surely founded rules of calculating ventilation heat loss as a function of influencing parameters.

Ventilation efficiency.

Reviews a research project which has the objective of establishing:< 1. Expressions for ventilation efficiency< 2. Methods for measuring ventilation efficiency< 3. Rules for acheiving efficient ventilation.< Derives expressions for ventilati

Natural ventilation of parking garages.

A combination of a wind-tunnel investigation and a mathematical simulation technique conducted on models of two-storey parking garage situated beneath alarge block of buildings (consisting of houses, shopping centre and offices) shows that wind penetrating the partly open garage facades can provide sufficient ventilation. Studies the effects on ventilation of varying the open area of the facades and of fitting openings in the garage roofs. Measures the effect of such ventilation means on air quality close to buildings.

Some effects due to variations in turbulence integral length scales on the pressure distribution on wind-tunnel models of low-rise buildings.

Describes results from wind-tunnel tests on models of the Building Research Establishment's experimental building at Aylesbury. The use of several scale models of this building in uniform and in simulated atmospheric boundary-layer flows together with the results from the full-scale experiments allow an assessment of the effect of variations in the ratio of the longitudinal- turbulence integral length scale to body dimension.

Factories.

Reviews methods of energy conservation in factories. States that excessive infiltration is unlikely to be the cause of high energy consumption, but that the most significant loads imposed by infiltration probably occur through open loading bays. Suggests the installment of double door lobbies to overcome this. Says the ideal factory heating system would include mechanical ventilation, with outside air mixed with warm "roof level" air. Describes potential sources of energy wastage and ways of rectifying this situation.

Energy efficient houses - an integrated approach.

Outlines the design of 6 energy efficient houses in Co. Kildare by the Electricity Supply Board, Ireland. The aim of the project is to collect and disseminate information on the costs and benefits of energy efficient houses. The houses will be monitored both occupied and unoccupied over a number of years, using a microcomputer on-site, with the required parameter values eventually being processed on a mainframe computer. Includes a description of the methods to be used in minimizing natural ventilation losses eg improved window joinery, entry point lobbies and appropriate draught sealing.

Air tightness in terraced houses.

Outlines a method for measuring the air leakage through the surface exteriors of an apartment, by adjusting the pressure of the adjoining apartments to that of the test apartment, so that no air leakage occurs through adjoining walls.

Design and construction of low energy houses in Saskatoon.

Describes details of wall and foundation designs that have been used in constructing super-insulated houses on the Canadian prairies. One trend has been the development of the double framing system in which two sets of wall studs are used one

Changing the ventilation pattern of a house.

Two series of pressurisation and ventilation measurements have been made in a low-energy house. One of the objectives of the work was to assess the extent to which the ventilation pattern of the house could be improved by modifying its leakage distribution. The first series of measurements was interpreted to understand the ventilation pattern and to make recommendations for the modifications. The second series was used to find out the effects of the modifications.

Continuous measurements of air infiltration in occupied dwellings.

Reports on a measurement system developed by the Institute of Technology at Tastrup Denmark, involving a microcomputer- controlled system for registering air change rates using tracer gas (nitrous oxide) according to the constant concentration method. The system is designed for measuring and metering tracer gas in up to 10 separate rooms (using an infrared gas absorption detector). It operates through automatic data logging on a floppy disc and can run without supervision for extended periods (up to six days).