HOTCAN - A computer program for estimating the space heating requirements of residences.

Lists the HOTCAN computer program devised for use in the Division of Building Research (NRC) program on low energy houses. It is written in BASIC and is capable of estimating the space heating requirements of residences. Gives basic equations and assumptions, and weather data required, along with a listing of the program and a sample run.

Industrial ventilation - a review and update.

Reviews technical progress being made in the industrial ventilation field by different investigators through out the world. Subjects reviewed and updated include natural ventilation, local exhaust ventilation, specialised ventilation techniques (dilution, air jets, air curtains, recirculation of filtered air, tracers for ventilation studies) and mine ventilation. Presents typical applications of the new technology to solving industrial ventilation problems, and identifies areas requiring further research and development.

Methods for control of indoor air quality.

Identifies alternative methods available to control indoor air pollutant exposures. Describes the performance characteristics of ventilation systems and of air cleaning devices used in mixed modes for ventilation of occupied spaces. Reviews models for predicting effectiveness of several alternative modes, with field trial validation results cited where available. Briefly reviews previous confined-space studies as points of departure for consideration of necessary air quality, ventilation and air cleaning.

Ventilation for control of indoor air quality - a case study.

Describes a test carried out in the Fridley, MN, Junior High School Music Dept. to obtain air quality, energy and subjective response data on an Automatic Variable Ventilation System. Devises a control system with both CO2 and temperature inputs to control the use of outdoor air. Infiltration measurements lead to a quantitative measure of ventilation efficiency, which in turn lead to recommendations for air circulation patterns in rooms. The measured ventilation efficiency enables energy and CO2 models to fit measured data. Finds energy savings of approx. 20% in this application.

A CO2-controlled ventilation system.

Describes a system installed in the EKONO office building in Helsinki which allows the amount of CO2 in the exhaust air to control the ventilation rate. Uses a CO2 indicator, and adjusts the mixture of exterior and recirculated air so that the amount of CO2 during working hours is kept on ca 700 ppm. Describes use of equipment during winter 1981-82, when exterior air flow is registered. Measures the proportion of CO2 locally in order to study occasional variations that may occur. Studies the proportion of other pollutants in the room air with a gas chromatograph.

The effects of ventilation on residential air pollution due to emissions from a gas-fired range.

Shows the usefulness of a model for extrapolating environmental chamber results on pollutant emissions from combustion appliances to determine indoor pollutant concentrations in actual residences. Investigates the effects of infiltration, whole-house ventilation, and spot ventilation on pollutant levels. Results show that a range hood is the most effective means of removing pollutants emitted from a gas-fired range; removal rates vary from 60%-87%.

Low-infiltration housing in Rochester New York-A study of air-exchange rates and indoor air quality.

Studies a sample of 58 occupied homes in Rochester NY to assess 1. the effectiveness of construction techniques designed to reduce air leakage 2. the indoor air quality and air-exchange rates in selected airtight houses and 3. the impact on

Air infiltration measurements in a home using a convenient perfluorocarbon tracer technique.

Using miniature perfluorocarbon tracer (PFT) sources and miniature passive samplers, tests conducted in the lab and in a typical home successfully demonstrate the utility of the PFT kit as a means for implementing wide-scale infiltration meas

The influence of ventilation on indoor/outdoor air contaminants in an office building.

Studies a modern energy efficient office building in a series of experiments with mobile laboratories connected on-line with the building. Measures inorganic air contaminants (CO, CO2, NO2). Makes off-line measurements of volatile organic con

Indoor climate in low-ventilated day care institutions.

Carries out measurements of indoor atmospheric environment in a day nursery and a kindergarten in Denmark, where natural air infiltration supplies the room with only 1-2 m3 fresh air per person and hour under the prescribed occupancy. Duplicates situation under controlled conditions in a climate chamber. Results indicate unacceptably high concentrations of carbon-dioxide, and show the need for more elaborate building design in airtight buildings.