Commercial building ventilation measurements using multiple tracer gas.

A unique multiple tracer experimental system has been developed and utilized within commercial buildings to monitor ventilation rates, air exchange efficiency, ages of air (at multiple indoor locations), flow rates of supply and outside air, and percent outside air in supply airstreams. The multiple tracer technique also makes it possible to determine the fractions of air at a monitoring point that entered the building through a particular air handler and by infiltration.

Integral mass balances and pulse injection tracer technique.

Tracer gas techniques for measuring airflow rates in building systems are considered. These techniques are classified in terms of tracer gas injection strategy employed and mass balance relationships used to analyze measured tracer concentration data. The discussion focuses on one class of tracer techniques - the pulse injection techniques - based upon pulse injection strategies and integral mass balance relationships.

Air motion in the vicinity of air supply devices for displacement ventilation.

In displacement ventilation systems, air flow rates, temperature and the design of the air supply device strongly influence the parameters which decide the thermal comfort. This paper reviews experiments and theoretical models which show the connection between t.hese parameters. It is indicated that the Archimedes number of the supply air is the parameter which decides the air velocity in the area close to the floor. (The Archimedes number is the ratio between buoyancy and inertia forces).

Ventilation generated by a fluctuating pressure differential.

Ventilation produced by fluctuating pressure differences across a building appears to have received little attention . Such fluctuations are produced by gustiness of the wind or turbulence in the flow around a building. An experimantal study has been performed on a laboratory model to investigate unsteady flows through apertures simulating those in the fabric of a building .

Ventilation strategies in the case of polluted outdoor air situations.

Outdoor air pollution can have a bearing on the effectiveness of indoor air and the quality of ventilation. There is a pressing need to reflect on the potential type and effect of occurrences (e.g. smog, or chemical accidents) and to develop technical, operational and organisational measures which must be taken with mechanical ventilation units in the case of polluted outdoor air situations. A polluted outdoor air situation is present when a ventilation process leads to the intake of pollutants in the interior and to the enrichment of these pollutants to an unacceptably high concentration.

Natural airflows between roof, subfloor and living spaces.

This paper is concerned with natural air flows between major construction cavities in New Zealand houses. A two tracer technique was developed to measure infiltration rates in the subfloor (crawl space), the living space and roof space, together with air flow rates connecting these zones. Five experimental houses were chosen to represent expected extremes in air flow resistance between subfloor and roof space.

Experimental analysis of air diffusion in a large space.

An experimental study in reduced scale model for ventilation inside a sheep-fold has been studied. The ventilating system consist of two slots in opposite side walls and one in the roof, Two-dimensional jet are generated by the wind effect and temperature difference acting upon the sheep-fold.

Ventilation by demand.

   

Pages