Ventilation design for a bus station.

The paper presents the development of a ventilation scheme for a large bus station and passenger interchange in Bilbao, Spain. The main objective of the design was to ensure that pollution free conditions could be achieved within an enclosed waiting area that opened up on to, and was surrounded by, a semi-enclosed pick-up space, where there could be large number of buses with their engines running. Initial thoughts were to use natural ventilation, architectural and other constraints made this impossible so mechanical ventilation became necessary.

Market analysis of sensors for the use in demand controlled ventilating systems.

In the framework of a project of the International Energy Agency (IEA) , IEA-Annex XVIII - Demand Controlled Ventilating (DCV) Systems, which started in fall 1987, a review of the state of the art of already existing DCV systems and devices has been undertaken by all participating countries. This paper is concerned with air quality sensors which may be suitable to control air quality on demand. The dominant contaminants are not only variing in different kinds of buildings (dwellings, schools, stores etc.) but also from room to room due to different ways of utilizing the spaces.

Natural ventilation for crown court: developing statistical assessment techniques at the design stage.

The ventilation performance of a proposed naturally-ventilated court-room was predicted and assessed on a statistical basis with regard to the local meteorological conditions. Summertime ventilation was to be provided via an underfloor duct and controllable vents at roof levels, under the action of wind and buoyancy forces. Wind pressure coefficients expected on the external facade of the building were obtained from wind tunnel measurements on a scale model.

Flow conditions in a mechanically ventilated room with a convective heat source.

The ventilation of a test room (LxWxH = 5.4x3.6x2.4 m) with a wall mounted heat source is investigated for two different air terminal devices. The properties of each air terminal device are described by measuring the velocity decay of the primary wall jet below the ceiling. The velocity distribution in the plume above the heat source has been measured at different heat loads as a function of the distance to the wall and the distance to the heat source.

Field experiences of airborne moisture transfer in residential buildings.

This paper deals with field experience of airborne moisture transfer problems in houses. Two types of phenomena are discussed in more detail; the infiltration of moist air from crawl spaces and the propagation of moist air produced in kitchens. A modified depressurisation test is described to determine the air tightness of ground floors. A case study is briefly discussed where different remedial measures have been tested to evaluate the moisture removal effectiveness in kitchens.

Examinations about the air humidity in lived dwellings depending on different air ventilation systems using a new characteristic value.

This work deals with problems of the air humidity in inhabited dwellings. A new approach is presented here which renders the definite diagnosis of humidity problems possible. The room air humidity from two buildings with different air ventilation systems with eight dwellings each is examined, The efficiency of the different ventilation systems is presented applying the new value, the so called "standardized room air humidity".

IEA Annex XIV: Energy and Condensation.

This paper reviews research activities undertaken in the framework of IEA Annex XIV, "Energy and Condensation". It outlines the objectives and working scheme. The importance of ventilation as an influencing factor and a remedial measure is investigated. The central theme of the IEA workshop, held in Leuven in September, 1985, was the problem of condensation.

The influence of a controlled natural ventilation on the indoor radon decay products concentration: a case study.

Air exchange rates in occupied buildings are difficult to assess due to their dependence on a multitude of climatic parameters and inhabitant behaviour. Moreover, the assessment of the influence of the air exchange rate on the radon progeny concentration is hampered by the diurnal and seasonal fluctuations of the indoor radon levels.

Analysis of the influence of topography on climatic exposure of buildings (Climatological Data).

This text contains comments to the poster presented at the 9th AlVC Conference in Gent, Belgium. The project under consideration in the poster (Climatological Data Transfer) is one of the numerous research fields of the Swiss ERL program (Energierelevante Luftströmungen in Gebaüde - Energy Relevant Air Flow in Buildings).

A ventilation concept for future dwelling houses.

To avoid the shortcomings and problems that occur in today's ventilation systems a ventilation concept for future dwelling-houses is under development. The concept responds to the way of living and building in the future. The real living functions are chosen to design principles, that's why the system has to be capable of operating at varying air flow rates. The building in the future is based on a hierarcical modulated system, from which, with a small set of standard components can be assembled versatile alternatives.

Pages